Análise experimental da eficiência das fibras de aço no reforço ao cisalhamento de vigas em concreto armado / Experimental analysis of the efficiency of steel fibres for shear strength of reinforced concrete beams

Submitted by Ivone Costa (mivone@ufpa.br) on 2018-06-26T18:07:37Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_AnaliseExperimentalEficiencia.pdf: 5243784 bytes, checksum: ac60c0405cc863a22e420bb17ac32c99 (MD5) / Approved for entry into archive by Ivone Costa (mivone@ufpa.br) on 2018-06-26T18:10:46Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_AnaliseExperimentalEficiencia.pdf: 5243784 bytes, checksum: ac60c0405cc863a22e420bb17ac32c99 (MD5) / Made available in DSpace on 2018-06-26T18:10:46Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_AnaliseExperimentalEficiencia.pdf: 5243784 bytes, checksum: ac60c0405cc863a22e420bb17ac32c99 (MD5)
Previous issue date: 2016-08-29 / O presente estudo avalia a eficiência das fibras de aço no reforço ao cisalhamento de
vigas em concreto armado. Para esse fim, serão apresentadas algumas recomendações
normativas e uma pesquisa experimental. No que diz respeito à análise das recomendações
normativas, serão discutidas cinco propostas, RILEM TC 162-TDF (2003), CECS 38 (2004),
JSCE (2008), EHE 08 (2010) e MODEL CODE (2010). Nesse contexto, a performance
dessas propostas foi avaliada a partir do parâmetro Vexp/Vteo, que relaciona, respectivamente,
os resultados experimentais, os quais foram coletados da literatura, compondo um banco de
dados (BD), e os resultados teóricos, definidos pelas recomendações normativas. Para o
programa experimental, foram avaliadas quatro vigas, sendo uma de referência (sem fibras)
e três em concreto reforçado com fibras de aço (CRFA). Ressalta-se que todas as vigas foram
reforçadas ao cisalhamento com uma taxa de armadura mínima. Entre as vigas em CRFA, é
importante comentar que será avaliada a influência do consumo de fibras (Cf) adicionado à
massa de concreto, que irá variar em 0,5% (≈40 kg/m3), 0,8% (≈60 kg/m3) e 1,0% (≈80
kg/m3) e a possibilidade de substituir parcialmente, ou completamente, o reforço
convencional (estribos) pelo mecanismo de reforço proporcionado pelas fibras de aço do
CRFA. Em relação à analise teórica, concluiu-se que as recomendações normativas MODEL
CODE (2010), CECS 38 (2004) e JSCE (2008), ofereceram os resultados mais acertados,
com Vexp/Vteo≈1,0, contudo, a JSCE (2008) foi a mais penalizada segundo a versão modificada
do DPC (Demerit Points Classification), proposto originalmente por COLLINS (2001).
RILEM TC 162-TDF (2003) se comportou de forma conservadora e a EHE 08 (2010)
apresentou resultados mais dispersos. Em relação aos ensaios experimentais, embora tenha
sido registrado um acréscimo de resistência na ordem de 20%, para o concreto com Cf=1,0%,
nos ensaios de compressão axial, contudo, o ganho mais expressivo registrado foi quanto a
ductilidade e tenacidade do CRFA, ao ponto de mudar o modo de ruptura das vigas, de
cisalhamento (viga de referência) para flexão (vigas com CRFA). / The present study aims to assess the efficiency of steel fibres for shear strength of
reinforced concrete beams. For this purpose, some design guidelines were discussed together
with an experimental research. For the guidelines analysis, five proposals are presented,
RILEM TC 162-TDF (2003), CECS 38 (2004), JSCE (2008), EHE 08 (2010) and MODEL
CODE (2010). Within this analysis, the proposals performance were assess from the Vexp/Vteo
parameter, which corresponds, respectively, the experimental results, which will be collected
from the scientific literature, composing a database (DB), and the theoretical results, which
are estimated according to the design guidelines. For the experimental research, four beams
are evaluated, where one beam is the reference one (no fibres), and the others are built with
steel fibres reinforced concrete (SFRC). It is important to note that all beams are reinforced
for shear strength by a minimum amount of web reinforcement (stirrups). For the SFRC
beams, two conditions will be discussed. Firstly, the influence of the fiber content (Cf) added
to the concrete, which range in 0,5% (≈40 kg/m3), 0,8% (≈60 kg/m3) and 1,0% (≈80 kg/m3)
and finally, the possibility to replace conventional web reinforcement (stirrups) by steel
fibres reinforcement. The theoretical analysis, it was concluded that the guidelines MODEL
CODE (2010), CECS 38 (2004) and JSCE (2008), have provided the best results agreed with
Vexp / Vteo≈1,0, however, JSCE (2008) was the most penalized according to the modified
version of the DPC (Demerit Points Classification), proposed originally by Collins (2001).
RILEM TC 162-TDF (2003) behaved conservatively and EHE 08 (2010) showed more
dispersed results. In relation to experimental research, although it was recorded a resistance
increases of 20% for concrete with Cf = 1.0%, the axial compression tests, however, the most
significant gain was recorded as ductility and toughness the SFRC, to the point of changing
the way of breaking the beams, shear (reference beam) for bending (beams with SFRC).

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.ufpa.br:2011/10065
Date29 August 2016
CreatorsGOMES, Lana Daniele dos Santos
ContributorsOLIVEIRA, Dênio Ramam Carvalho de, MORAES NETO, Bernardo Nunes de
PublisherUniversidade Federal do Pará, Programa de Pós-Graduação em Engenharia Civil, UFPA, Brasil, Instituto de Tecnologia
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Source1 CD ROM, reponame:Repositório Institucional da UFPA, instname:Universidade Federal do Pará, instacron:UFPA
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.003 seconds