Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2013-01-08T17:27:39Z
No. of bitstreams: 2
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5)
Dissertacao_AmplificadorRegistroPotenciais.pdf: 1573358 bytes, checksum: c63088be31befb563c0bd2c13bcb865f (MD5) / Approved for entry into archive by Ana Rosa Silva(arosa@ufpa.br) on 2013-01-16T15:29:40Z (GMT) No. of bitstreams: 2
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5)
Dissertacao_AmplificadorRegistroPotenciais.pdf: 1573358 bytes, checksum: c63088be31befb563c0bd2c13bcb865f (MD5) / Made available in DSpace on 2013-01-16T15:29:40Z (GMT). No. of bitstreams: 2
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5)
Dissertacao_AmplificadorRegistroPotenciais.pdf: 1573358 bytes, checksum: c63088be31befb563c0bd2c13bcb865f (MD5)
Previous issue date: 2005 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Vários órgãos do corpo humano manifestam suas funções por meio de atividades elétricas. A medição desses e de outros biopotenciais pode fornecer indícios importantes que permitem o estudo do funcionamento real dos órgãos. Tais medições não constituem tarefa simples porque envolvem aquisição de dados de sinais cujas amplitudes podem ser na faixa entre 1 μV e 10 mV e também porque, no ambiente em que são feitos esses registros, estão presentes diversos tipos de sinais interferentes que causam degradação da relação sinal/ruído. Logo, o projeto do condicionador de biopotencial deve ser cercado de cuidados para que o circuito final reúna as melhores características de desempenho. Neste trabalho apresenta-se um estudo da origem dos biopotenciais, suas características, os circuitos utilizados para ganho e filtragem do sinal, além das interferências presentes nos sistemas de medições e alguns circuitos para redução desses sinais. É desenvolvido então, um condicionador para registro de biopotenciais corticais com blocos de filtragem e ganho do sinal em até 40 000. Os testes com o condicionador foram realizados registrando o potencial cortical provocado visual e o eletroencefalograma, e nos resultados experimentais é possível observar um desempenho satisfatório do equipamento. / Many organs in the human body manifest their functions through electric
activities. Measurements of these and other biopotentials can provide vital clues
that permits study as real functions of the organs. These measurements are not
an easy task because envolves extremely low amplitudes data acquisition,
between 1 μV and 10 mV, and also because these bioelectric recordings are
often disturbed by an excessive level of interference presents, resulting in
signal/noise degradation. Therefore, the biopotential amplifier project must be
associated with precaution to final circuit can meet great characteristics in such
signals measureming. This work shows a study about biopotentials origins, their
characteristics, circuits used in signal amplifiering and filtering, interferences
present in measurement systems and some circuits used to reduce such
interferences. Thereafter, is developed a cortical biopotential amplifier with
filtering and gain blocks. The tests with amplifier where realized by registering a
visual evoked potential and the electroencephalogram. In the experimental
results is possible to observe a satisfactory equipment performance.
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.ufpa.br:2011/3331 |
Date | 02 February 2005 |
Creators | CARDOSO, Marcelo Ramos |
Contributors | SILVA, Ivan Sebastião de Souza e |
Publisher | Universidade Federal do Pará, Programa de Pós-Graduação em Engenharia Elétrica, UFPA, Brasil, Instituto de Tecnologia |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UFPA, instname:Universidade Federal do Pará, instacron:UFPA |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.007 seconds