Previous issue date: 1980-04 / Apresenta-se, inicialmente, um estudo abrangente dos vários tipos de células de pressão total, utilizadas em solos e em fronteiras rígidas (paredes-diafragma, estacas-pranchas etc), o que permitiu apresentar uma classificação geral destes instrumentos. Procura-se estabelecer os valores limites aceitáveis para os fatores que influenciam o desempenho das células. Analisam-se vários procedimentos de instalação das células, salientando a importância desta fase nos resultados obtidos. Faz parte das atividades de pesquisa da área de Mecânica dos Solos da COPPE/UFRJ a instrumentação de campo, destacando-se a instalação de células de pressão total em paredes-diafragma de escoramento da vala do METRÔ/RIO. Descreve-se o procedimento
de instalação de células de dois tipos e sua repercussão nos resultados. Comenta-se a calibração de um dos tipos de células. Finalmente, como consequência destes estudos, apresenta-se o projeto de um protótipo de célula de pressão total. Esta célula, do tipo de fluido confinado, que o Autor projetou, não necessitará de material importado. Pretende-se que o seu desenvolvimento e calibração na COPPE/UFRJ, conduza ao projeto final de uma célula de utilização confiável no campo, em solo ou em fronteiras rígidas. / A comprehensive study of design and performance of earth pressure cells as used in soils and rigid boundaries
(diaphragm walls, sheet piling etc) was firstly done, and a general classification of these instruments was presented. It was sought to estabilish limiting values for the differents factors that influence the performance of these cells. An analysis of different installation procedures and how they influence the results was made. Researchers from COPPE/UFRJ have developed a few projects requiring field instrumentation. In two of these jobs, two types of earth pressure cells were installed in the excavations for the subway of Rio de Janeiro. The measurements are described. Also shown the calibration of one of the cell types. Finally, as a result of these studies, the Author designed a prototype of earth pressure cell. It is a confined fluid cell type, and its design avoids using foreign imported material. It is hoped that the development and calibration of this cell will permit to attain an improved design of earth pressure cell to be used in soil and rigid boundaries.
Identifer | oai:union.ndltd.org:IBICT/oai:pantheon.ufrj.br:11422/2999 |
Date | 04 1900 |
Creators | Ribas, José Bonifácio Mader |
Contributors | Soares, Márcio Miranda |
Publisher | Universidade Federal do Rio de Janeiro, Programa de Pós-Graduação em Engenharia Civil, UFRJ, Brasil, Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa em Engenharia |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UFRJ, instname:Universidade Federal do Rio de Janeiro, instacron:UFRJ |
Rights | info:eu-repo/semantics/openAccess |