Return to search

Especiação de compostos nitrogenados empregando a espectrometria de absorção molecular de alta resolução com fonte contínua (HR-CS MAS) / Speciation of nitrogenous compounds employing high-resolution continuum-source molecular absorption spectrometry (HR-CS MAS)

O presente trabalho apresenta uma nova técnica de especiação de compostos nitrogenados em amostra ambientais e de alimentos, utilizando a técnica de absorção molecular de alta resolução com fonte contínua (HR-CS MAS). O íon nitrito foi determinado por meio da geração de vapor (CVG) de NO acoplado a HR-CS MAS, na presença de ácido clorídrico e de ácido ascórbico. Fatores como a temperatura da cela de quartzo, vazão do gás de arraste, vazão do sistema CVG e concentração dos ácidos foram otimizados nessa etapa. Métodos de especiação de nitrito e nitrato foram estudados, empregando a fotorredução do nitrato à nitrito - irradiação de luz ultravioleta (UV) - nas amostras contendo nitrato em meio tamponado com cloreto de amônio em pH 7,97, na presença de EDTA. Dessa maneira, a concentração de nitrato, empregando o processo de redução, se soma à concentração de nitrito anterior, sendo especiado por meio da subtração da concentração final da inicial. O p-nitrofenol (PNP) foi determinado por meio da quebra da ligação C-N na estrutura, empregando radiação UV na presença de peróxido de hidrogênio em pH 11,8, gerando nitrito, o qual foi determinado por meio da redução à vapor de NO. As condições otimizadas para o método proposto visando as determinações (especiação) por meio da formação de NO foram, (I) Determinação de nitrito: linha de absorção 214,803 nm, temperatura da cela de quartzo de 600 oC, vazão do gás de arraste de 6 L.H-1, vazão do sistema CVG 8,0 mL.min-1, [HCl] 3,0 mol.L-1 e [Ác. Ascórbico] 3,5% (m.v-1); (II) Determinação de nitrato: [NH4Cl] 2,0 mol.L-1 em pH 7,97, [EDTA] 1,0 mmol.L-1 e 20 segundos de irradiação UV (254 nm e 15 W). (III) Determinação de PNP: [H2O2] 1,0 mmol.L-1 em pH 11,8 e 20 segundos em irradiação UV (254 nm e 15 W). Curvas de calibração foram construídas, de maneira a avaliar o comportamento das espécies em cada condição de determinação seletiva, e, posteriormente, o método foi aplicado nas amostras. Foram analisadas tanto a água de conserva quanto o alimento sólido, seco em estufa à 70 oC até massa constante e logo após, triturado em água deionizada ultrapura à 70 oC por 40 minutos. As amostras foram centrifugadas e filtradas em seguida. Testes de adição e recuperação foram realizados nas amostras, para avaliar a eficiência do método e as possíveis fontes de interferência no sistema. Os valores de R2, LOD (mg.L-1) e LOQ (mg.L-1) foram, respectivamente, de 0,9903; 0,047 e 0,16 para o nitrito; de 0,9904; 0,090 e 0,30 para nitrato e de 0,9957; 0,034 e 0,11 para PNP. / The present work presents a new technique for the speciation of nitrogenous compounds in environmental and food samples, using the high-resolution continuum-source molecular absorption technique (HR-CS MAS). The nitrite ion was determined by the generation of vapor (CVG) of NO coupled to HR-CS MAS in the presence of hydrochloric acid and ascorbic acid. Factors such as the temperature of the quartz cell, carrier gas flow, CVG system flow and acid concentration were optimized in this step. Nitrite and nitrate speciation methods were studied, using the photoreduction of nitrate to nitrite - irradiation of ultraviolet light (UV) - in the samples containing nitrate in buffered medium with ammonium chloride at pH 7,97, in the presence of EDTA. In this way, the nitrate concentration, using the reduction process, is added to the concentration of the previous nitrite, being speciated by subtraction of the final concentration of the initial one. P-nitrophenol (PNP) was determined by breaking the C-N bond in the structure, employing UV radiation in the presence of hydrogen peroxide at pH 11.8, generating nitrite, which was determined by the reduction to NO vapor. The optimized conditions of the proposed method for the determinations (speciation) through NO formation were: (I) nitrite determination: absorption line in 214,803 nm, quartz cell temperature of 600 oC, carrier gas flow of 6 L.H-1, CVG system flow of 8.0 mL.min-1, [HCl] 3.0 mol.L-1 and [Ascorbic acid] 3.5% (m.v-1); (II) Determination of nitrate: [NH4Cl] 2.0 mol.L-1 at pH 7.97, [EDTA] 1.0 mmol.L-1 and 20 seconds of UV irradiation (254 nm and 15 W). (III) Determination of PNP: [H2O2] 1.0 mmol.L-1 at pH 11.8 and 20 seconds in UV irradiation (254 nm and 15 W). Calibration curves were constructed in order to evaluate the behavior of the species in each condition of selective determination, and, later, the method was applied in the samples. Both the conserve water and the solid food, oven dried at 70 oC up to constant mass, were analysed and then crushed in ultra-pure deionized water at 70 oC for 40 minutes. The samples were centrifuged and then filtered. Addition and recovery tests were performed in the samples to evaluate the efficiency of the method and possible sources of interference in the system. The values of R2, LOD (mg.L-1) and LOQ (mg.L-1) were, respectively, 0.9903; 0.047 and 0.16 for nitrite; 0.9904; 0.090 and 0.30 for nitrate and 0.9957; 0.034 and 0.11 for PNP. / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES

Identiferoai:union.ndltd.org:IBICT/oai:10.254.254.39:tede/1021
Date31 January 2017
CreatorsGOUVÊA, Luis Felipe Costa
ContributorsFRESCHI, Gian Paulo Giovanni, http://lattes.cnpq.br/7759622872412835, LUCCAS, Pedro Orival, VEIGA, Márcia Andréia M. S. da
PublisherUniversidade Federal de Alfenas, Instituto de Ciência e Tecnologia, Brasil, UNIFAL-MG, Programa de Pós-Graduação em Ciência e Engenharia Ambiental
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Formatapplication/pdf
Sourcereponame:Biblioteca Digital de Teses e Dissertações da UNIFAL, instname:Universidade Federal de Alfenas, instacron:UNIFAL
Rightshttp://creativecommons.org/licenses/by-nc-nd/4.0/, info:eu-repo/semantics/openAccess

Page generated in 0.0025 seconds