Return to search

Quantificação de sinais de MRS do cérebro in-vivo para classificação de tumores / Automatic in-vivo MRS signal quantification for the classification of brain tumors

Orientador: Gabriela Castellano / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin. / Made available in DSpace on 2018-08-12T12:39:12Z (GMT). No. of bitstreams: 1
CuellarBaena_SandraPatricia_M.pdf: 2971806 bytes, checksum: 993051b37ed11a93fc4c48a83e24003d (MD5)
Previous issue date: 2008 / Resumo: Este trabalho visou o estudo e validação de técnicas de pre-processamento e quantificação de dados provenientes da técnica de Espectroscopia por Ressonância Magnética (MRS, do inglês Magnetic Resonance Spectroscopy), obtidos do cérebro humano in vivo, para a extração de informação que fosse clinicamente relevante para o estudo e diagnostico de tumores cerebrais. Para isso, foi feito o estudo da técnica com base na literatura, incluindo a revisão dos aspectos físicos envolvidos, estudando os métodos computacionais utilizados para o pre-processamento e quantificação dos dados, e os aspectos bioquímicos dos metabólicos de interesse presentes no cérebro humano, passiveis de serem quantificados através da técnica. Especificamente, foi estudado um método de quantificação de dados de MRS, o método. AMARES (Advanced Method for Accurate, Robust and Efficient Spectral fitting of MRS data), aplicado na quantificação de dados de MRS adquiridos de sujeitos controles e pacientes portadores de tumores cerebrais, provenientes de uma base de dados do Laboratório de Neuroimagem (LNI - Hospital das Clinicas - UNICAMP). Isso foi feito utilizando o software de domínio público jMRUI (http://sermn02.uab.es/mrui/)[1], que possui o método AMARES já implementado. Estes resultados foram comparados com resultados provenientes de uma quantificação manual desses mesmos dados, realizada previamente como parte do projeto de doutorado da Dra. Andréia Vasconcellos (atual docente do Depto. de Radiologia da FCM/UNICAMP)[2]. Foi verificada a concordância entre os dois métodos de quantificação, e também a viabilidade de usar os resultados da quantificação com o método automático para alem de diferenciar entre os grupos de pacientes e controles, realizar a separação dos Pacientes com tumores em diferentes grupos. Obteve-se que os resultados obtidos com o método automático foram mais precisos e consistentes que os obtidos com o método manual, e permitiram uma melhor classificação dos tipos de tumores. Adicionalmente, foram incluídos neste trabalho os resultados do estudo de perfis metabólicos ex vivo em tumores cerebrais pediátricos através da técnica HR-MAS (do inglês High Resolution Magic Angle Spinning). Este estudo adicional foi realizado no Laboratório de Imagem Molecular da Faculdade de Medicina da Universidade de Valencia (Espanha) através do Programa Santander de Mobilidade Internacional e financiado através de uma bolsa do Banco Santander-Banespa. / Abstract: The aim of this work was to study and validate techniques for pre-processing and quantificating Magnetic Resonance Spectroscopy data, obtained in vivo from the human brain, in order to get information clinically useful for the study and diagnosis of brain tumors. Therefore, a literature-based study of the technique was made, including a review of the Physics concepts involved, the data acquisition process in the scanner and the computational methods used to pre-process and quantificate the spectral data, as well as the biochemical aspects of the metabolites of interest in the human brain that can be detected by this technique. Special attention was given to the AMARES (Advanced Method for Accurate, Robust and Efficient Spectral fitting of MRS data) method for MRS data quantification, which was studied and applied to the quantification of data from control subjects and patients with brain tumors. The data came from a database of the Neuroimaging Laboratory (LNI - Hospital das Clinicas - UNICAMP). The quantification with AMARES was made through the jMRUI software (http://sermn02.uab.es/mrui/) [1], a public domain software for processing and quantification of MRS data. These results were compared to the results obtained with a manual quantification of the same data, previously done as part of the PhD thesis work of Dr. Andreia Vasconcellos (lecturer from the Radiology Department of the School of Medicine, UNICAMP) [2]. The agreement between the results from both quantification methods was verified, as well as the feasibility of using the automatic quantification results to differentiate among tumor types, besides differentiating between patients and controls. Results obtained by the automatic method were more accurate and consistent than those obtained by the manual method allowing a better classification. Additionally, in this work were included the results of the study of ex vivo and in vivo metabolic profiling in pediatric brain tumors using the HR-MAS (High Resolution Magic Angle Spinning) technique. This study was carried out in the Molecular Imaging Laboratory, School of Medicine at the University of Val¿encia (Spain), within the Santander-Banespa Bank International Exchange Program. / Mestrado / Física / Mestre em Física

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/277860
Date07 October 2008
CreatorsCuellar Baena, Sandra Patricia
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Castellano, Gabriela, 1970-, Zeri, Ana Carolina Mattos, Covolan, Roberto José Maria
Publisher[s.n.], Universidade Estadual de Campinas. Instituto de Física Gleb Wataghin, Programa de Pós-Graduação em Física
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format142 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0029 seconds