Return to search

Estudo da distribuição de temperatura em motores de bombas centrífugas submersas / Study of motor temperature distribution of electrical submersible pumps

Orientadores: Antonio Carlos Bannwart, Marcelo Moreira Ganzarolli / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica e Instituto de Geociências / Made available in DSpace on 2018-08-22T03:35:14Z (GMT). No. of bitstreams: 1
Betonico_GustavodeCarvalho_M.pdf: 2382106 bytes, checksum: a84e8f76b2a2dcf28078dd9283ecef59 (MD5)
Previous issue date: 2013 / Resumo: Neste trabalho foi desenvolvido um modelo para determinação da temperatura do motor de uma bomba centrífuga submersa (BCS) sob condições variáveis de vazão e carga. Este leva em consideração o comportamento acoplado entre o motor, a bomba e o sistema de produção. Assim, dada uma frequência ajustada no variador de frequência, a temperatura do motor é determinada como resultado do equilíbrio entre a produção de calor, calculada a partir da potência que a bomba demanda do motor, e a extração do calor, calculada a partir da vazão. Neste modelo, considera-se a BCS instalada num módulo de bombeamento submarino localizado perto do poço produtor. Foi estudada a transferência de calor por convecção no módulo de bombeio, onde um escoamento descendente ocorre no anular externo entre o revestimento e a camisa de refrigeração e um fluxo ascendente ocorre no anular interno entre a camisa de refrigeração e o motor. Um estudo de transferência de calor por convecção foi elaborado comparando modelos baseados no perfil de temperatura plenamente desenvolvido com modelos que consideram o desenvolvimento da camada limite térmica. Uma vez que o único ponto de medição da temperatura se localiza na extremidade inferior do enrolamento de estator, o modelo desenvolvido neste trabalho também determina a distribuição de temperatura do motor. Um estudo de caso foi realizado com diversas viscosidades de óleo e frações de água. Os resultados mostram a elevação da temperatura do motor, quando sua velocidade é continuamente aumentada. Também se mostrou que, negligenciar os efeitos do desenvolvimento da camada limite térmica, quando ocorre escoamento laminar, pode resultar num motor superaquecido, onde na verdade, a temperatura máxima do motor é muito menor do que o seu limite superior. Modelos baseados no perfil temperatura plenamente desenvolvidos sofrem de imprecisão, quando utilizados em aplicações de fluidos viscosos, devido ao grande comprimento entrada térmica / Abstract: A model to predict the motor temperature of an electrical submersible pump, under variable conditions of flow rate and loading, has been developed. This model takes into account the coupled behavior between motor, pump and production system. Thus, given a frequency set in the variable speed drive, the motor temperature is determined as a result of the equilibrium between the heat generation, calculated from the power that the pump demands from the motor, and the heat extraction, calculated from the flow rate. In this model, the electrical submersible pump is supposed to be installed in a subsea pumping module located near the producer well. It has been studied the convective heat transfer in the pumping module, where a downward flow occurs in the external annulus between the casing and the shroud, and an upward flow happens in the internal annulus between the shroud and the motor. A convective heat transfer study has been run comparing models based on fully developed temperature profile and models that consider the development of the thermal boundary layer. Since the only point of temperature measurement is located at the lower end of the stator winding, the model developed in this work also determines the temperature distribution of the motor. A case study has been run with several oil viscosities and water cut. The results show a motor temperature rise when motor speed is continuously increased. It is also showed that, when laminar flow occurs, neglecting the effect of the thermal boundary layer development may result in an overheated motor prediction where actually, motor maximum temperature is much smaller than its upper limit. Fully developed temperature profile models suffer of inaccuracy when used in viscous fluid applications, due to its big thermal entry length / Mestrado / Explotação / Mestre em Ciências e Engenharia de Petróleo

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/265663
Date22 August 2018
CreatorsBetônico, Gustavo de Carvalho
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Ganzarolli, Marcelo Moreira, 1952-, Bannwart, Antonio Carlos, 1955-, Altemani, Carlos Alberto Carrasco, Estevam, Valdir
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Mecânica, Universidade Estadual de Campinas. Instituto de Geociências, Programa de Pós-Graduação em Engenharia Mecânica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format114 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0028 seconds