Otimização de linhas de transmissão para manobra de abertura monopolar - análise da influência dos parâmetros transversais do sistema de compensação reativa / Optimization of transmission lines to single-phase opening maneuver - analysis of the influence of transversal parameters of shunt reactive compensation system

Orientador: Maria Cristina Dias Tavares / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-25T04:28:30Z (GMT). No. of bitstreams: 1
ZevallosAlcahuaman_MiltonElvis_D.pdf: 2479285 bytes, checksum: 4c1c5f42e8da1a073caee7cb88308479 (MD5)
Previous issue date: 2013 / Resumo: Uma solução bastante utilizada para reduzir a corrente de arco secundário nas linhas aéreas de transmissão em extra-alta-tensão após a ocorrência de faltas monofásicas não permanentes é a inserção de um reator de neutro no arranjo dos reatores dos bancos de compensação reativa em derivação da linha. Muitas vezes estes reatores de neutro não são otimizados, de modo que reatores com valores típicos são especificados nos projetos de linhas de transmissão aéreas, baseados simplesmente no seu nível de tensão, mas sem considerar as especificidades das linhas, como as suas características físicas ou o seu comprimento. A especificação inadequada do reator de neutro pode resultar em correntes de arco secundário elevadas, o que, em última análise, pode reduzir a taxa de sucesso da manobra de religamento monopolar. Além disto, o custo do sistema de compensação pode ser maior do que o necessário. A tese apresenta uma extensa análise de sensibilidade dos principais parâmetros que influenciam no dimensionamento de um tronco de transmissão longo, especificamente do nível de compensação mais adequado e do valor ótimo do reator de neutro. Destaca-se na pesquisa o desenvolvimento de uma representação dos componentes de um sistema de transmissão através de quadripolos trifásicos com o intuito de obter a resposta sustentada durante o desequilíbrio. Através desta representação foi possível identificar a relação entre o reator de neutro ótimo e os parâmetros transversais da linha de transmissão, assim como a influência direta entre o nível de compensação do sistema com o valor do reator de neutro otimizado. Adicionalmente foram identificados comprimentos limites para linhas não compensadas de diferentes níveis de tensão de modo a ainda apresentar alta probabilidade de sucesso para a manobra monopolar. Simulações de faltas monofásicas foram realizadas utilizando dados provenientes de linhas típicas do sistema elétrico brasileiro / Abstract: A widely used solution to reduce secondary arc current in the overhead transmission lines in EHV after single-phase non permanents faults is the insertion of a neutral reactor in the arrangement forming part of the shunt reactive compensation of the line. Frequently in Brazilian electrical system, neutral reactors are not optimized, so that reactors with typical values are specified in the project of overhead transmission lines based on their voltage level, but without considering the specifics line parameters, as their physical characteristics or their length. The specification of unsuitable neutral reactor can result in high secondary arc currents, which eventually diminishes the success rate of single-phase automatic reclosure (SPAR) maneuver. Moreover, the cost of the compensation system may be larger than necessary. This paper presents an extensive sensitivity analysis of the main parameters that influence the project of a long transmission trunk, specifically the most appropriate level of compensation and the optimal value of the neutral reactor. It is noteworthy the development of a transmission system components representation using three-phase two-ports networks in order to obtain sustained response during unbalance. Through this analysis it was possible to identify the relationship between the shunt reactor and the optimized neutral parameter and the influence of the compensation level with the neutral reactor optimized value. Additionally the maximum lengths of non-compensated lines that would have high probability of success of SPAR maneuver were identified. Simulations of single-phase faults were performed using data from typical lines of the Brazilian electric system / Doutorado / Energia Eletrica / Doutor em Engenharia Elétrica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/260990
Date03 January 2013
CreatorsZevallos Alcahuaman, Milton Elvis, 1974-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Tavares, Maria Cristina Dias, 1962-, Paz, Marcos de Araujo, Camara, Alessandra de Sa e Benevides, Silva, Luiz Carlos Pereira da, Valero, Patricia Mestas
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Elétrica e de Computação, Programa de Pós-Graduação em Engenharia Elétrica
Source SetsIBICT Brazilian ETDs
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format131 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0031 seconds