Use SNA instead of VNA to characterize indoor channel : implementing and rms theory

In this report we focus on the use of an economical way on how Scalar Network Analyzer (SNA) works instead of Vector Network Analyzer (VNA) to estimate the phase angle of signals in indoor channel. This is detailed in RMS delay theory and simulation section, experimental is designed in the according Experiment Design section, where we also state the required measurements known from the math part. In our work, data are recorded both from two different channel characteristics. Method of achieving amplitude is by using deconvolution theory. The condition of applying Hilbert transform are highlighted as impulse response h(t) in time domain should be causal.  The recorded data amplitude is computed by Hilbert Transform, and therefore validate the condition using Inverse Discrete Fourier Transform (IDFT) back to time domain to achieve h(t). Power delay profile P(t) is therefore presented afterwards. In paper calculations of rms delay τrms  of the channel which is the most important variable are also performed, the results calculated from different windowing truncation and the LOS and NLOS characteristics are compared in discussion and conclusion section, it also includes Opinions of window functions chosen for the phase estimation.

Identiferoai:union.ndltd.org:UPSALLA1/oai:DiVA.org:hig-7780
Date January 2010
CreatorsLai, Jingou, Liu, Che
PublisherHögskolan i Gävle, Avdelningen för elektronik, matematik och naturvetenskap, Högskolan i Gävle, Avdelningen för elektronik, matematik och naturvetenskap
Source SetsDiVA Archive at Upsalla University
LanguageEnglish
Detected LanguageEnglish
TypeStudent thesis, info:eu-repo/semantics/bachelorThesis, text
Formatapplication/pdf
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0019 seconds