Return to search

Desenvolvimento de um biossensor mimético descartável para pesticidas organofosforados e carbamatos para o controle de qualidade de águas de abastecimento / Development of a disposable mimetic biosensor for organophosphorus and carbamate pesticides aiming quality control of water supply

A enzima acetilcolinesterase (AChE) tem sido amplamente aplicada no desenvolvimento de biossensores para detecção de pesticidas. No entanto, a aplicação de tais dispositivos é limitada devido à falta de robustez, que está associada com a baixa estabilidade enzimática, além de seu alto custo. Uma alternativa às enzimas é a utilização de moléculas sintéticas que mimetizem o comportamento enzimático, com menor custo e maior estabilidade; tais moléculas são denominadas moléculas biomiméticas. Neste trabalho são apresentados três potenciais catalisadores: o ácido [4-(1E)etanohidrazonoil]benzóico, o iodeto de pralidoxima (2-PAM) e o polímero polihidroxamicalcanoato (PHA); com grupos funcionais alfa nucleófilos hidrazona, oxima e ácido hidroxâmico, respectivamente. Tais moléculas foram avaliadas baseando-se em dois critérios para classificação de biomiméticos da AChE: 1) catálise da hidrólise do substrato acetiltiocolina (ATCh) e 2) interação com pesticida organofosforado. O método espectrofotométrico de Ellman revelou que o polímero PHA foi a molécula mais eficiente, uma vez que a constante de velocidade de segunda ordem obtida foi de 13867 mol-1 L s-1, 5 vezes superior a da 2-PAM e 232 vezes a da hidrazona. Posteriormente, todas as moléculas foram avaliadas por método espectrofotométrico em relação à interação com o organofosforado paraoxon. Apenas o PHA apresentou interação nas condições estudadas. Cálculos teóricos mostraram como ocorre a aproximação entre o PHA e ATCh, e com o paraoxon. Diante dos resultados obtidos, o PHA foi a molécula biomimética escolhida para aplicação no sensor eletroquímico para detecção de organofosforados. Primeiramente, o PHA foi imobilizado na superfície de um eletrodo impresso descartável a partir da formação de uma blenda com o polímero polietileno glicol metil éter, evitando sua solubilização. A oxidação da tiocolina formada a partir da catálise do ATCh realizada pelo PHA imobilizado foi verificada em 0,46 V vs Ag/AgCl, por voltametria de pulso diferencial. A equação obtida a partir da curva de calibração referente ao intervalo de concentração de paraoxon de 1,0 a 10,0 µmol L-1 foi I(%) = [4,8x106 C (mol L-1) + 0,8169]×100 (R2 = 0,99969), com limite de detecção de 3,63x10-7 mol L-1. Amostras de água de abastecimento foram analisadas, com concentrações adicionadas de paraoxon de 3,0; 6,0 e 8,0 µmol L-1, com recuperação de 115%; 106% e 94,5%, respectivamente. Os resultados apresentados mostraram que foi possível desenvolver um sensor eletroquímico biomimético para detecção de pesticida paraoxon. / Acetylcholinesterase enzyme (AChE) has been widely applied in biosensor development for pesticide detection. However, the application of those biosensors is limited due to their lack of robustness associated with low enzymatic stability and AChE high cost. An alternative to enzymes, it is the use of synthetic molecules which mimic enzymatic behavior, besides its low cost and superior stability, those are classified as biomimetic molecules. In this work is presented three potential catalysts: [4-(1E)ethanehydrazonoyl]benzoic acid, pralidoxime iodide (2-PAM), and polyhydroxamicalkalnoate polymer (PHA) with alpha nucleophile functional groups, such as hydrazone, oxime, and hydroxamic acid, respectively. The aforementioned molecules were evaluated based on two criteria for classification as AChE biomimetic: 1) catalysis of acetylthiocholine substrate (ATCh) hydrolysis and 2) interaction with organophosphorus pesticide. Spectrophotometrical Ellman´s method revealed that PHA polymer was the most efficient one, since its second order rate constant was 13867 mol-1 L s-1, which was 5 times superior than 2-PAM one and 232 times higher than hydrazone. Then, each molecule was analyzed through spectrophotometric method to verify the interaction with paraoxon organophosphorus pesticide. Only the PHA exhibited such interaction in the studied conditions. Theoretical calculations showed how the approach between PHA and ATCh, and also with paraoxon occurred. Regarding the obtained results, PHA was the chosen biomimetic molecule to be applied in the electrochemical sensor for organophosphorus detection. First of all, PHA was immobilized on the surface of disposable screen printed electrode through blend formation with polyethylene glycol methyl ether (mpEG), avoiding PHA dissolution. The oxidation of thiocholine generated towards ATCh catalysis performed by immobilized PHA was verified at 0.46 V vs Ag/AgCl by differential pulse voltammetry. The linear equation obtained through calibration curve for paraoxon concentration range of 1.0 to 10.0 µmol L-1 was I(%) = [4.8x106 C (mol L-1) + 0.8169]×100 (R2 = 0.99969), with limit of detection of 3.63x10-7 mol L-1. Water supply samples were analyzed considering the added paraoxon concentrations of 3.0; 6.0 e 8.0 µmol L-1, recovering 115%; 106% and 94.5%, respectively. The presented results showed that a biomimetic electrochemical sensor was successfully developed for detection of paraoxon organophosphorus pesticide.

Identiferoai:union.ndltd.org:IBICT/oai:teses.usp.br:tde-26042016-141206
Date26 February 2016
CreatorsLívia Flório Sgobbi
ContributorsSergio Antonio Spinola Machado, Emanuel Carrilho, João Marcos Madurro, Hideko Yamanaka
PublisherUniversidade de São Paulo, Química, USP, BR
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Sourcereponame:Biblioteca Digital de Teses e Dissertações da USP, instname:Universidade de São Paulo, instacron:USP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0025 seconds