Evaluation of the Inelastic Rotation Capability of Flush End-Plate Moment Connections

An experimental investigation was conducted to study the inelastic rotation capability of flush end-plate moment connections. Seven specimens representing two-bolt and four-bolt flush end-plate configurations were tested under cyclic loading. "Quasi-static" or "slow-cyclic" loading histories suggested by SAC and the Applied Technology Council were used to load the specimens. Experimental results for maximum moment resisted by the connections were compared with analytical predictions. Moment strengths of the connections were calculated using yield-line theory to predict end-plate yielding and maximum bolt force calculations including prying action. Experimental results were also compared to previous research with regards to strength and stiffness. The inelastic rotation of connections was calculated and conclusions were drawn on the compliance of these connections with current AISC specifications. / Master of Science

Identiferoai:union.ndltd.org:VTETD/oai:vtechworks.lib.vt.edu:10919/31592
Date02 April 1999
CreatorsBoorse, Mark Richard
ContributorsCivil Engineering, Murray, Thomas M., Easterling, William Samuel, Cousins, Thomas E.
PublisherVirginia Tech
Source SetsVirginia Tech Theses and Dissertation
Detected LanguageEnglish
TypeThesis
Formatapplication/pdf
RightsIn Copyright, http://rightsstatements.org/vocab/InC/1.0/
Relation01thesis.pdf