Submitted by Ginamara Lima (ginaj@pucrs.br) on 2012-05-31T18:51:40Z
No. of bitstreams: 1
438761.pdf: 1117817 bytes, checksum: 66a7869995a918890ef53d9067f6dc69 (MD5) / Made available in DSpace on 2012-05-31T18:51:40Z (GMT). No. of bitstreams: 1
438761.pdf: 1117817 bytes, checksum: 66a7869995a918890ef53d9067f6dc69 (MD5) / Introdução: Este estudo in vitro avaliou a capacidade de centralização do preparo, bem como o desgaste distorção e a fratura de três tipos de instrumentos rotatórios de níquel-titânio (Ni-Ti) – Wizard CD Plus (WP), Wizard Navigator (WN) e BioRace(BR). Metodologia: Foram utilizadas 90 raízes mésio-vestibulares (MV) de primeiros molares superiores (1ºs MS) e 10 conjuntos de cada tipo de instrumento rotatório. A sobreposição de imagens tomográficas de feixe cônico pré e pós-instrumentação avaliaram a capacidade de centralização do preparo, a 2,0, 4,0, 6,0 e 8,0mm do ápice. Os instrumentos foram avaliados em microscopia eletrônica de varredura (MEV), antes e após até o terceiro uso, na sua ponta e a 5mm desta. Os dados foram analisados pelo Teste de Kruskal-Wallis, complementado pelo Teste de Tukey (P<0.05). Resultados: Houve transporte do canal radicular em todos os grupos, não havendo diferença estatística entre os mesmos (P>0.05). Não houve fratura e distorção a 5mm da ponta nos instrumentos analisados. O grupo BR apresentou mais distorção na ponta do instrumento do que o grupo WP (P=0,011). Houve mais desgaste do instrumento no grupo WP do que no BR (P<0,001). Ocorreu aumento progressivo da distorção na ponta do instrumento e do desgaste em relação ao uso no grupo BR (distorção P=0,026 e desgaste P<0,001), assim como do desgaste no grupo WP (P<0,001). Conclusão: Nenhum dos sistemas rotatórios empregados foi capaz de proporcionar preparos centralizados e o uso progressivo dos instrumentos aumenta a ocorrência de distorção e desgastes em sua topografia. / Introduction: This in vitro study evaluated the capacity of centralization of the preparation, as well as the wear, distortion and fracture of three rotary nickel-titanium (Ni-Ti) systems – Wizard CD Plus (WP), Wizard Navigator (WN) and BioRace(BR). Methodology: Were used 90 mesiobuccal roots (MV) of first upper molars (MS). The overlap of tomographic images before and after instrumentation was used to evaluate the transport of the preparation, at 2.0, 4.0, 6.0 and 8.0 mm from the apex. The instruments were observed by SEM before and after the third use, at its tip and at 5 mm of it. The data were analyzed by Kruskal-Wallis, complemented by Tukey test (P<0.05). Results: There was transport of the root canal in all groups, with no statistical difference between them (P> 0.05). There was no fracture and distortion at 5mm from the tip of the instruments. The group BR exhibited more distortion at the tip than the group WP (P = 0.011). There was more wear of the instrument in the group WP than in the BR (P <0.001). There was a progressive increase in distortion at the tip (P = 0.026) and of the wear (P <0.001) compared to the use in the group BR, as well as the wear in the group WP (P<0.001). Conclusion: None of the rotary systems employed was able to provide centralized preparation and the progressive use of the instruments did not favor the occurrence of fracture despite having increased the occurrence of distortion and wear.
Identifer | oai:union.ndltd.org:IBICT/urn:repox.ist.utl.pt:RI_PUC_RS:oai:meriva.pucrs.br:10923/1035 |
Date | January 2012 |
Creators | Bürgel, Marília Ostermann |
Contributors | Pelisser, Fabiana Vieira Vier |
Publisher | Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | English |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da PUC_RS, instname:Pontifícia Universidade Católica do Rio Grande do Sul, instacron:PUC_RS |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0023 seconds