The thesis deals with an energy simulation of a ground heat exchanger (GHE) in classical and brine performance, which is used as an accessory of warm air heating system recovery in a low-energy family house. On basis of simulation results, the benefits of both heat exchangers were assessed. Furthermore, the energy and economics savings of heat recovery coupled with GHE were evaluated. Comparing the investment costs, the profitability of each investment were assessed and recommendations for the operation, implementation and appropriateness were outlined.
Identifer | oai:union.ndltd.org:nusl.cz/oai:invenio.nusl.cz:229058 |
Date | January 2010 |
Creators | Sokola, Robert |
Contributors | Kolbábek, Antonín, Jaroš, Michal |
Publisher | Vysoké učení technické v Brně. Fakulta strojního inženýrství |
Source Sets | Czech ETDs |
Language | Czech |
Detected Language | English |
Type | info:eu-repo/semantics/masterThesis |
Rights | info:eu-repo/semantics/restrictedAccess |
Page generated in 0.0018 seconds