The thesis is focused on the design of a self-powered sensor for measurement of water flow rate and temperature in water pipelines. The key block of this thesis is the construction of an electric generator powered by excitation with turbulent flow. The generated voltage should power the sensor's circuits and allow water flow rate measurements. Throughout the development, three prototypes of generators powered by turbulent flow were created. Turbulences were not created by an insertion of a bluff body but by inner geometry of the pipeline elements. Maximum power of 10,66 uW was generated at flow rate of 8 m3/h. Afterwards, a prototype of water flow rate and temperature sensor was assembled. Energy self-sufficiency of the device at common flow rates was not achieved using the chosen procedure. The designed flow rate measurement method is suitable for an approximate flow rate estimation.
Identifer | oai:union.ndltd.org:nusl.cz/oai:invenio.nusl.cz:221233 |
Date | January 2015 |
Creators | Šindelář, Jindřich |
Contributors | Růžek, Václav, Dřínovský, Jiří |
Publisher | Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií |
Source Sets | Czech ETDs |
Language | Czech |
Detected Language | English |
Type | info:eu-repo/semantics/masterThesis |
Rights | info:eu-repo/semantics/restrictedAccess |
Page generated in 0.0019 seconds