Influência da injeção de argamassa nos condutos das armaduras das peças de concreto protendido

Submitted by Fatima Fonseca (fatima.fonseca@sibi.ufrj.br) on 2017-09-06T17:43:07Z
No. of bitstreams: 1
142409.pdf: 2376648 bytes, checksum: 774ed826413091d6301da72dee1d1f0c (MD5) / Made available in DSpace on 2017-09-06T17:43:07Z (GMT). No. of bitstreams: 1
142409.pdf: 2376648 bytes, checksum: 774ed826413091d6301da72dee1d1f0c (MD5)
Previous issue date: 1976-04 / Verifica a influência da injeção da argamassa nos condutos (bainhas) das armaduras das peças de concreto protendido, com armadura pós-tracionada, objetivando conhecer-se o comportamento das estruturas tanto em serviço quanto na ruptura. Foram ensaiadas, até a ruptura, oito vigas isostáticas de seção duplo T assimétrico, das quais apenas quatro tiveram o conduto da armadura de protensão injetado. Além da injeção no conduto, adotou-se como parâmetro de variação a tensão inicial aplicada na armadura de protensão. A análise dos resultados é feita através a apresentação de diagramas comparativos relacionando o comportamento das vigas injetadas e não injetadas, tanto em serviço quanto próximo à ruptura. Observou-se ser bastante coerente a redução de até 30%, especificada pelo CEB-FIP para a segurança à ruptura das vigas que possuem os condutos não injetados, uma vez que, na pesquisa realizada, em um dos pares de vigas confrontadas, verificou-se ter sido essa redução de 20%. / Verifying the influence of the injection of mortar in the ducts of the tendons of prestressed concrete beams, with the purpose of finding out the behavior of structures both in service and at the point of rupture. Eight simple span beams of double T section were tested to the point of rupture, but only four of those had some morter injected in the ducts of their prestressed tendons. Besides injection in the duct, some initial tension applied on prestressed tendons was adopted as a variation parameter. The analysis of results is accomplished through the presentation of comparative diagrams in which the behavior of bounded beams and unbonded beams is related to each other both in service and close to the point of rupture. The reduction of up to 30% as specified by CEB-FIP for the security of unbonded beams against rupture was considered coherent and just, since, during research, a reduction of 20% was observed in one of the pairs of confronted beams,

Identiferoai:union.ndltd.org:IBICT/oai:pantheon.ufrj.br:11422/2787
Date04 1900
CreatorsNetto Junior, Ladislau
ContributorsCarneiro, Fernando Luiz Lobo Barboza
PublisherUniversidade Federal do Rio de Janeiro, Programa de Pós-Graduação em Engenharia Civil, UFRJ, Brasil, Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa em Engenharia
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFRJ, instname:Universidade Federal do Rio de Janeiro, instacron:UFRJ
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0012 seconds