Submitted by Cássio da Cruz Nogueira (cassionogueirakk@gmail.com) on 2017-03-16T13:00:29Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_AnaliseComportamentoMecanico.pdf: 3370614 bytes, checksum: f1b777107334ba0763714cfa70848d4f (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-03-20T15:38:48Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_AnaliseComportamentoMecanico.pdf: 3370614 bytes, checksum: f1b777107334ba0763714cfa70848d4f (MD5) / Made available in DSpace on 2017-03-20T15:38:48Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_AnaliseComportamentoMecanico.pdf: 3370614 bytes, checksum: f1b777107334ba0763714cfa70848d4f (MD5)
Previous issue date: 2015-09-25 / As fibras de aço nos tubos de concreto têm proporcionado melhores níveis de comportamento mecânico. Na região norte, singularmente em Belém do Pará, não há estudos sobre a viabilidade técnica desse recurso tecnológico, embora haja uma considerável deficiência de infra-estrutura urbana. Deste modo tornam-se relevantes realizar estudos sobre a alternativa tecnológica. Esse estudo busca analisar o comportamento mecânico dos tubos de concreto com fibras de aço, visando à viabilidade técnica de substituição dos tubos de concreto com armadura convencional. Na metodologia da pesquisa utilizaram-se fibras de aço no estado soltas e coladas em pente do tipo DRAMIX® 3D 65/35 e do tipo DRAMIX® 3D 80/60. Para cada tipo de fibra foram adotados teores de 20 kg/m³ (0,25%), 30 kg/m³ (0,38%) e 40 kg/m³ (0,50%), em massa e fração volumétrica, respectivamente. A dimensão de todos os tubos de concreto foi de diâmetro de 600 mm, espessura de parede de 60 mm e comprimento útil de 1000 mm, e os corpos-de-prova cilíndricos de 100x200mm e prismáticos de 150x150x500mm e 150x150x550mm, que foram submetidos aos ensaios para avaliação de comportamento mecânico e durabilidade. Na produção do concreto com fibras houve a avaliação no estado fresco com abatimento de tronco de cone entre 0 e 10 mm. A dosagem do concreto com fibras foi a rotineiramente empregada pela empresa para o concreto sem fibras, e a dosagem das fibras ocorreu de acordo com a regra da mistura. Como resultados obtiveram que os tubos de concreto com fibras do tipo 80/60 soltas em todos os teores e coladas em pente nos teores de 0,38% e 0,50%, atingiram a mínima carga de ruptura e pós-fissuração estabelecidas pela NBR 8900 (ABNT, 2007), deste modo seriam tecnicamente viáveis quanto à substituição de tubos de concreto armado convencionalmente, dentro das condições e especificações desse estudo. / The steel fibers in the concrete pipes have provided better mechanical performance levels. In the northern region, uniquely in Belem, no studies on the technical feasibility of this technological resource, although there is considerable deficiency of urban infrastructure. Thus become relevant conduct studies on alternative technology. This study seeks to analyze the mechanical behavior of concrete pipes with steel fibers, aiming at the technical feasibility of replacing the concrete pipe with conventional armor. The research methodology we used steel fibers in loose state and glued comb DRAMIX® 3D type 65/35 and 80/60 DRAMIX® 3D type. For each fiber type were adopted contents of 20 kg / m³ (0.25%), 30 kg / m³ (0.38%) and 40 kg / m³ (0.50%) by weight and volume fraction, respectively. The size of all concrete pipes was 600 mm diameter, wall thickness of 60 mm and effective length 1000 mm, and the cylindrical bodies of the test piece of 100x200mm and prismatic of 150x150x500mm and 150x150x550mm, which were subjected to the tests for mechanical behavior evaluation and durability. In the production of concrete with the fibers was reviewed in the fresh state with frustoconical rebate between 0 and 10 mm. The dosage of concrete with fibers was routinely employed by the company for concrete without fibers, and the strength of the fibers takes place under the rule of the mixture. The results obtained that the concrete pipe with fiber type 80/60 loose at all levels and pasted comb the levels of 0.38% and 0.50%, reached the minimum breaking load and post-cracking set by the NBR 8900 (ABNT, 2007), thus would be technically feasible as the replacement of reinforced concrete pipes conventionally, under the conditions and specifications of this study.
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.ufpa.br:2011/7931 |
Date | 25 September 2015 |
Creators | OLIVEIRA, Marco Antonio Barbosa de |
Contributors | MACEDO, Alcebíades Negrão, POMPEU NETO, Bernardo Borges |
Publisher | Universidade Federal do Pará, Programa de Pós-Graduação em Engenharia Civil, UFPA, Brasil, Instituto de Tecnologia |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | English |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UFPA, instname:Universidade Federal do Pará, instacron:UFPA |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0025 seconds