Return to search

Abordagem regulatória do programa de monitoração da eficácia da manutenção para usinas nucleoelétricas

Submitted by Almir Azevedo (barbio1313@gmail.com) on 2014-01-14T13:53:12Z
No. of bitstreams: 1
dissertacao_mestrado_ien_2009_01.pdf: 953803 bytes, checksum: 4e82f430afc69c7c9b6decdb25a18898 (MD5) / Made available in DSpace on 2014-01-14T13:53:12Z (GMT). No. of bitstreams: 1
dissertacao_mestrado_ien_2009_01.pdf: 953803 bytes, checksum: 4e82f430afc69c7c9b6decdb25a18898 (MD5)
Previous issue date: 2009 / A geração de energia elétrica por meio de usinas nucleares requer que esta
instalação seja segura, confiável e esteja disponível nos momentos de seu
funcionamento. Para este objetivo, um programa de manutenção adequado, eficaz e
bem elaborado torna-se uma ferramenta muito útil e essencial à proprietária da
usina. Entretanto, é necessário atender aos requisitos regulatórios na
implementação deste programa que monitora a eficácia desta manutenção. Existem
normas brasileiras com requisitos gerais a serem obedecidos. Os guias regulatórios
internacionais detalham bem estes requisitos mas é necessário verificar se a
metodologia pode ser integralmente empregada aquí no Brasil ou precisa ser
adaptada para nosso uso. Assim, o guia americano NUMARC 93-01, que detalha
como poderia ser implementado um programa para esta monitoração, sugere
algumas metodologias. Nesta tese, as metodologias Delphi e Análise Probabilística de Segurança foram resumidamente incluídas porque foram elas escolhidas para
implementar esta monitoração.em uma usina brasileira Os resultados que estão
sendo obtidos mostram que, sob o aspecto regulatório, esta é uma metodologia que
atende às nossas normas e fornece muitos resultados para um bom gerenciamento
da usina. / The electrical power generation using nuclear power plants requires this installation
being safety, reliable and available for the working periods. For this purpose, an
adequate, effective and well conducted maintenance program makes an essential
and useful tool to the owner of the plant. However, it is necessary to follow the
regulatory requirements for this program implementation which monitores this
maintenance effectiveness. There are brazilian norms requirements which must be
followed. The international regulatory guides establish these requirements in good
details but it is necessary to verify if this methodology for implementing can be totally
applied here in Brazil. Then, the american guide NUMARC 93-01 which details how
can be implemented a program for this monitoring, shows some methods for using. In this thesis, the Delphi and Probabilistic Safety Analysis were briefly included
because they were prefered for implementing this monitoring.in a Brazilian plant. The
results which are being obtained show that, looking the regulatory aspects, the
NUMARC 93-01 follows our regulations and gives good results for the plant
management.

Identiferoai:union.ndltd.org:IBICT/oai:carpedien.ien.gov.br:ien/561
Date03 1900
CreatorsVAJGEL, Stefan
ContributorsSALDANHA, Pedro Luiz da Cruz, PEREIRA, Cláudio Márcio do Nascimento Abreu, ARAÚJO, Jefferson Borges de, LAPA, Celso Marcelo Franklin
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional do IEN, instname:Instituto de Engenharia Nuclear, instacron:IEN
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0015 seconds