Return to search

AvaliaÃÃo de mÃtodo espectrofotomÃtrico comercial para determinaÃÃo de trihalometano em Ãgua de abastecimento humano / Evaluation of commercial espectrofotomÃtrico method for determination of trihalometano in water of human supplying

Conselho Nacional de Desenvolvimento CientÃfico e TecnolÃgico / A formaÃÃo de trihalometanos na Ãgua de abastecimento humano representa um grande problema para a saÃde pÃblica, visto que esses compostos sÃo suspeitos de serem carcinogÃnicos. A tÃcnica referenciada para determinaÃÃo de trihalometanos na Ãgua à a cromatografia gasosa, onde se utiliza o detector de captura de elÃtrons. Essa tÃcnica apresenta algumas desvantagens que inviabilizam sua implantaÃÃo em uma estaÃÃo de tratamento de Ãgua (ETA). Um mÃtodo espectrofotomÃtrico desenvolvido pela empresa Hach pode auxiliar a operaÃÃo de uma ETA quanto ao monitoramento dos trihalometanos, pois esse mÃtodo analÃtico tem menor custo, uma resposta imediata dos resultados e à de fÃcil implantaÃÃo e operaÃÃo quando se compara com a cromatografia gasosa. Nesta pesquisa, foi realizada uma avaliaÃÃo do mÃtodo espectrofotomÃtrico comercial por alguns parÃmetros do Instituto Nacional de Metrologia, NormalizaÃÃo e Qualidade Industrial (INMETRO) e foi dividida em trÃs etapas. Na primeira etapa, realizou-se um teste para certificar-se que o agente redutor neutralizava todo o cloro residual presente na Ãgua. Foi adicionado tiossulfato de sÃdio na Ãgua final da ETA GaviÃo e determinou-se concentraÃÃo de âzeroâ mg L-1 na determinaÃÃo de cloro residual. A segunda etapa consistiu na implantaÃÃo e operaÃÃo da anÃlise de trihalometanos por cromatografia gasosa. Foram realizadas duas curvas utilizando dois padrÃes diferentes: um padrÃo de clorofÃrmio e um padrÃo de uma mistura contendo os quatro trihalometanos, todos com a mesma concentraÃÃo. Nessa etapa, todas as curvas construÃdas apresentaram um Ãndice de correlaÃÃo dentro da faixa exigida pelas normas do INMETRO e do mÃtodo. A terceira etapa consistiu na construÃÃo de curvas utilizando novamente os dois padrÃes, porÃm utilizando a tÃcnica espectrofotomÃtrica. Foram realizadas duas curvas de cada padrÃo pelo mesmo analista e uma curva de cada padrÃo por outro analista. Com os dados obtidos, estudou-se a precisÃo, exatidÃo, robustez, seletividade, linearidade, faixa de trabalho e faixa linear. AlÃm disso, foram realizados testes de adiÃÃo de padrÃo e um teste para verificar a interferÃncia de diferentes matrizes na anÃlise. Constatou-se que o mÃtodo nÃo apresentou precisÃo, nem exatidÃo. Pequenas mudanÃas realizadas no procedimento analÃtico causaram alteraÃÃo no resultado, indicando falta de robustez do mÃtodo analÃtico, alÃm de ser extremamente suscetÃvel a erros aleatÃrios e, possivelmente, quantificar outros subprodutos da desinfecÃÃo / The formation of trihalomethanes in human water supply represents a big problem to the public health, since these compounds are suspected carcinogens. The technique referred for determination of trihalomethanes in water is gas chromatography, which uses an electron capture detector. This technique has some disadvantages that unfeasible the implantation in the water treatment plant. A spectrophotometry method developed by Hach can assist the operation of a water treatment plant on the monitoring of trihalomethanes, since this analytical method has a lower cost, an immediate response by the results and is easy to implantation and operate when compared with gas chromatography. In this research, an evaluation of commercial spectrophotometry method was realized for some parameters of the Instituto Nacional de Metrologia, NormalizaÃÃo e Qualidade Industrial (INMETRO) and was divided into three stages. In the first stage, performed a test to make sure that the reducing agent neutralize any residual chlorine in the water. Sodium thiosulfate was added treated water of GaviÃoÂs water treatment plant, to determine the concentration of âzeroâ mg L-1 in the determination of residual chlorine. The second stage consists in the implantation and operation of the analysis of trihalomethanes by gas chromatography. Two curves were performed using two different standards: a standard of chloroform and a standard of a mixture containing the four trihalomethanes, all with the same concentration. At this stage, all curves constructed showed a correlation coefficient in the range required by the rules of the INMETRO and of the method. The third step was the construction of curves by using again the two standards, but using the spectrophotometric method. Two curves of each standard by the same analyst and a curve of each standard of the other analyst were performed. With the data obtained, was studied the precision, accuracy, robustness, selectivity, linearity, working range and linear range. In addition, a standard addition test and a test for interference in the analysis of different matrices were performed. It was found that the method no had precision and accuracy. Small changes made in the analytical procedure caused change in the result, indicating lack of robustness of the analytical method, besides being extremely susceptible to random errors and possibly quantify other disinfection byproducts

Identiferoai:union.ndltd.org:IBICT/oai:www.teses.ufc.br:3927
Date17 November 2010
CreatorsVictor Cochrane Santiago Sampaio
ContributorsJose Capelo Neto, Francisco SuetÃnio Bastos Mota, Manoel do Vale Sales
PublisherUniversidade Federal do CearÃ, Programa de PÃs-GraduaÃÃo em Engenharia Civil, UFC, BR
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Formatapplication/pdf
Sourcereponame:Biblioteca Digital de Teses e Dissertações da UFC, instname:Universidade Federal do Ceará, instacron:UFC
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0037 seconds