Cavitation Limits and the Effect of Aeration on Cone Valves

Cavitation in cone valves can cause eventual valve failure. However, little data are available on cavitation limits for solid plug cone valves. Flow conditions were identified for a 6 inch cone valve where incipient, critical, incipient damage, and choking cavitation limits occurred at valve openings between 20 and 70 degrees. A description of how these limits are used to predict cavitation intensity is given. Air was used to reduce the damage levels. Aeration increased the allowable pressure drop for damage free operation 6 to 72 percent for valve openings less than 70 degrees. A chart is given for predicting when a cone valve will draw air. Location of the air injection point 1s not important as long as it is introduced into the separation zone.

Identiferoai:union.ndltd.org:UTAHS/oai:digitalcommons.usu.edu:etd-6118
Date01 May 1985
CreatorsMumford, Bart "L"
PublisherDigitalCommons@USU
Source SetsUtah State University
Detected LanguageEnglish
Typetext
Formatapplication/pdf
SourceAll Graduate Theses and Dissertations
RightsCopyright for this work is held by the author. Transmission or reproduction of materials protected by copyright beyond that allowed by fair use requires the written permission of the copyright owners. Works not in the public domain cannot be commercially exploited without permission of the copyright owner. Responsibility for any use rests exclusively with the user. For more information contact digitalcommons@usu.edu.