Return to search

Estudo prospectivo comparativo de duas modalidades de posicionamento do sensor de pH-metria esofágica prolongada: por manometria esofágica e pela viragem do pH / Comparative prospective study of two positioning modes of 24-hour esophageal pH monitoring: by esophageal manometry and by the pH step-up technique

Por padronização aceita internacionalmente, posiciona-se o sensor distal de pH-metria esofágica a 5 cm acima da borda superior do esfíncter inferior do esôfago, identificado por manometria esofágica. Porém, vários autores sugerem técnicas alternativas de posicionamento que prescindem da manometria; dentre essas, destaca-se a da viragem do pH. Esse tema é controverso: alguns autores consideram a técnica da viragem confiável, outros afirmam que não é. Considerando-se a polêmica existente e o pequeno número de trabalhos prospectivos com amostra e metodologia adequadas, idealizamos o presente estudo, que tem por objetivos avaliar a adequação do posicionamento do sensor distal de pH-metria baseado na técnica da viragem, analisando-se a presença, o grau e o tipo de erro de posicionamento que tal técnica proporciona e a influência da posição adotada pelo paciente durante a manobra. Foram estudados, de modo prospectivo, 1031 pacientes encaminhados para realização de pH-metria esofágica. Durante entrevista clínica, foram registrados os dados demográficos e as queixas clínicas apresentadas. Todos pacientes foram submetidos à manometria esofágica para localização do esfíncter inferior do esôfago e à técnica da viragem do pH, que consiste na introdução do sensor de pH-metria na câmara gástrica e na tração gradual do mesmo até que o pH vire para níveis superiores a 4. A identificação do ponto de viragem foi realizada de dois modos distintos, caracterizando dois grupos de estudo: com o paciente sentado (Grupo I - 450 pacientes) e em decúbito dorsal horizontal (Grupo II - 581 pacientes). Após a identificação do ponto de viragem, o sensor distal de pH-metria era posicionado na posição padronizada, baseada na localização manométrica do esfíncter. Registrava-se onde seria posicionado o sensor de pH se fosse adotada a técnica da viragem. Para avaliação da adequação do posicionamento, considerou-se que o erro é representado pela diferença (em centímetros) entre a localização padronizada e a localização que seria adotada caso fosse empregada a técnica da viragem. Considerou-se que o erro seria grosseiro se fosse maior que 2 cm. Analisou-se também o tipo de erro mais freqüente: se acima ou abaixo da posição padronizada. Observou-se que se fosse adotada a técnica da viragem, haveria erro no posicionamento do sensor em 945 pacientes (91,6%). Quanto ao grau de erro, haveria erro grosseiro em 597 (63,2%) casos. Em relação ao tipo de erro, o sensor seria posicionado abaixo do local padronizado em 857 (90,7%) pacientes. Em relação à interferência da posição adotada pelo paciente durante a técnica da viragem, observou-se que não houve diferença significante entre os grupos de estudo, em nenhum dos parâmetros analisados. Conclui-se que: 1. o posicionamento do sensor distal de pH-metria pela técnica da viragem não é confiável; 2. a técnica da viragem proporciona margem de erro expressiva; 3. o tipo de erro mais comum que tal modalidade técnica proporciona é o posicionamento mais distal do sensor, que pode superestimar a ocorrência de refluxo; 4. não há influência da posição adotada pelo paciente durante a realização da técnica da viragem do pH, na eficiência do método / By internationally accepted standardization, the esophageal pH-meter distal sensor is positioned 5 cm above the superior border of the esophagus lower sphincter, identified by esophageal manometry. However, several authors suggest alternative positioning techniques that leave out the manometry; among such techniques, the pH step-up is the one to be pointed out. This subject is controversial; some publications state that the step-up technique is not reliable while some others consider it reliable. Considering the existent controversy and the small number of prospective works with suitable sample and methodology, we have idealized the present study, that aims the evaluation of the suitability of the pH-meter distal sensor positioning based on the step-up technique, by analyzing the presence, the degree and the type of the error of positioning that such technique provides and the influence of the position adopted by the patient during the procedure. 1031 patients conducted to the esophageal pH-meter procedure were studied in a prospective way. During the clinical interview, the demographic data and the presented clinical complaints were registered. All the patients were submitted to both esophageal manometry in order to localize the esophagus lower sphincter and the pH step-up technique, that consists of the introduction of the pH-meter sensor in the gastric chamber and in the sensors gradual traction until the pH steps up to levels over 4. The step-up point was identified by two distinct ways, characterizing two study groups: with the setting patient (Group I - 450 patients) and in supine position (Group I I- 581 patients). After the step-up point identification, the pH-meter distal sensor was placed in the standard position, based on the sphincter manometric placement. It was registered where the pH sensor would be positioned if the step-up technique were adopted. To evaluate the positioning suitability, the error was considered to be represented by the difference (in centimeters) between the suitable placement (manometry) and the one that would be adopted in case the step-up technique were adopted. The positioning error was considered rough if it were larger than 2 cm. The most frequent type of error was also analyzed: if above or below the standard position. It was observed that if the step-up technique were adopted, there would be error in the sensor positioning in 945 patients (91.6%). In terms of error degree, there would be a rough error in 597 (63.2%) cases. Concerning the type of error, the sensor would be positioned below the standard place in 857 (90.7%) patients. As to the interference of the position adopted by the patient during the step-up technique, it was observed that there was no significant difference among the groups of study, in any of the analyzed parameters. It was concluded that: 1. the positioning of the pH-meter distal sensor by the step-up technique is not reliable; 2. the step-up technique provides expressive error margin; 3. the most common type of error that such technique mode provides is the placement of the sensor below the standard positioning, which may overestimate the reflux occurrence; 4. there is no influence in the position adopted by the patient during the pH step-up technique procedure, in terms of method efficiency

Identiferoai:union.ndltd.org:usp.br/oai:teses.usp.br:tde-29012009-132317
Date18 January 2008
CreatorsFrare, Rita de Cassia
ContributorsNasi, Ary
PublisherBiblioteca Digitais de Teses e Dissertações da USP
Source SetsUniversidade de São Paulo
LanguagePortuguese
Detected LanguagePortuguese
TypeDissertação de Mestrado
Formatapplication/pdf
RightsLiberar o conteúdo para acesso público.

Page generated in 0.0025 seconds