Return to search

Efeitos da recirculação de efluentes tratados no branqueamento de polpa celulósica Kraft / Effects of treated effluent recirculation on the bleaching plant of a Kraft pulp mill

Submitted by MARCOS LEANDRO TEIXEIRA DE OLIVEIRA (marcosteixeira@ufv.br) on 2018-07-18T12:40:02Z
No. of bitstreams: 1
textocompleto.pdf: 1133030 bytes, checksum: fc194935e221ab96b8cb35560cd00359 (MD5) / Made available in DSpace on 2018-07-18T12:40:02Z (GMT). No. of bitstreams: 1
textocompleto.pdf: 1133030 bytes, checksum: fc194935e221ab96b8cb35560cd00359 (MD5)
Previous issue date: 2018-03-15 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / O branqueamento é o estágio da produção de polpa celulósica kraft que gera maior carga hídrica poluente e muitas fábricas têm buscado minimizar ou até mesmo eliminar a quantidade de efluente gerado. O fechamento de circuitos d ́água vislumbra-se como uma opção atrativa para a redução do consumo de água e da geração de efluentes. O objetivo do presente trabalho foi avaliar a viabilidade técnica de utilizar efluentes tratados como água de lavagem nos estágios do branqueamento. A sequência D ht (EP)DP de branqueamento foi simulada em laboratório utilizando quatro tipos de água de lavagem: a) água deionizada, b) água branca (AB) da máquina de secagem, c) efluente de baixa carga orgânica (EBC) proveniente da planta química e do pátio de madeira da fábrica, tratado por decantação; e d) efluente de alta carga orgânica (EAC) tratado biologicamente por um processo de lodos ativados. Para alcançar alvura da polpa de 90% ISO, o consumo de ClO 2 da sequência completa de branqueamento foi de 8,1, 8,0, 16,3 e 13,8 kgClO 2 tas -1 ao utilizar água deionizada, AB, EBC e EAC, respectivamente. A viscosidade, n° kappa e o teor de ácido hexenurônico da polpa branqueada com os efluentes diminuíram em relação à polpa branqueada com água deionizada. Os testes físicos e ópticos dos papéis confeccionados não demonstraram alterações estatísticas significativas com a mudança do tipo de água utilizada para lavagem. Os filtrados dos estágios D ht e EP apresentaram valores de condutividade elétrica, cor, turbidez, DQO, SDT e teor de Ca, Fe, K, Na e Cu maiores para os branqueamentos realizados com os efluentes em relação às referências (água deionizada e AB). Não obstante, sua qualidade não compromete a eficiência da Estação de Tratamento de Efluentes (ETE). Conclui-se que foi possível utilizar efluente na lavagem dos estágios de branqueamento, uma vez que as qualidades dos filtrados gerados, da polpa branqueada e dos papéis confeccionados foram satisfatórias, havendo, contudo, um incremento no consumo de reagentes ao longo da sequência e, consequentemente, um aumento do custo de produção de polpa celulósica / The bleaching plant is the kraft pulp mill sector that generates the highest volume of effluents and many mills have sought to minimize or even eliminate this pollution source. The recycling of water can be seen as an attractive option to reduce water consumption and effluent generation. The objective of the present research was to evaluate the technical feasibility of using treated effluent as wash water in the bleaching stages. The bleaching sequence D ht (EP)DP was simulated in laboratory using four types of wash water: a) deionized water, b) whitewater (WW) from drying machine, c) low effluent organic load (LEL) from the chemical plant and wood yard of the mill and treated by sedimentation; and d) high organic load effluent (HEL) treated biologically by an activated sludge process. To achieve pulp brightness of 90% ISO, the consumptions of ClO 2 in the bleaching sequence were 8.1, 8.0, 13.8 and 16.3 kgClO 2 odt -1 when using deionized water, WW, LEL and HEL, respectively. The viscosity, kappa number and hexenuronic acid of the bleached pulp, when effluents were applied as wash water, decreased in comparison to the bleached pulp when deionized water was used. Physical and optical tests of the papers did not show any statistically significant difference whatever wash water used. The filtrates of D ht and EP stages presented values of electrical conductivity, color, turbidity, COD and Ca, Fe, K, Na and Cu content higher when effluent was used in relation to the references (deionized water and WW). Nevertheless, the filtrates quality would not jeopardize the Wastewater Treatment Plant (WTP) efficiency. It was possible to use effluent as wash water in the bleaching stages, since the filtrates and the paper produced with the bleached pulp complied with the quality standards. However, there was an increase in the consumption of chemicals in the bleaching sequence when effluents were used, and, consequently, an increase on the pulp production costs

Identiferoai:union.ndltd.org:IBICT/oai:localhost:123456789/20643
Date15 March 2018
CreatorsSantos, Erika Nascimben
ContributorsColodette, Jorge Luiz, Silva, Cláudio Mudadu
PublisherUniversidade Federal de Viçosa
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFV, instname:Universidade Federal de Viçosa, instacron:UFV
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0026 seconds