Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil, 2014. / Submitted by Ana Cristina Barbosa da Silva (annabds@hotmail.com) on 2014-10-22T17:42:45Z
No. of bitstreams: 1
2014_JuanGabrielBastidasMartinez.pdf: 1656961 bytes, checksum: 7869b12a771e890895d24b5a7af2d95c (MD5) / Approved for entry into archive by Tania Milca Carvalho Malheiros(tania@bce.unb.br) on 2014-10-31T16:03:20Z (GMT) No. of bitstreams: 1
2014_JuanGabrielBastidasMartinez.pdf: 1656961 bytes, checksum: 7869b12a771e890895d24b5a7af2d95c (MD5) / Made available in DSpace on 2014-10-31T16:03:20Z (GMT). No. of bitstreams: 1
2014_JuanGabrielBastidasMartinez.pdf: 1656961 bytes, checksum: 7869b12a771e890895d24b5a7af2d95c (MD5) / As Estações de Tratamento de Água (ETA) e de Esgoto (ETE) geram como subprodutosde sua operação uma grande quantidade de lodo, que é considerado resíduo sólido pela ABNT10.004/2004 (Associação Brasileira de Normas Técnicas). A disposição final dos resíduos, semum adequado gerenciamento, pode resultar em danos aos seres humanos e ao meio ambiente constituindo-se em passivo ambiental a evitar. Este trabalho teve como finalidade verificar a possibilidade de utilização dos referidos resíduos em concreto betuminoso usinado a quente proporcionando a sua melhoria de comportamento, sem levar em conta nessa fase inicial os custos diretos do tratamento e nem do passivo ambiental. Para possibilitar a incorporação dos resíduos lodos de ETA e de ETE no Concreto Asfáltico utilizou-se um moinho mecânico a fim de tornar o material passante pela peneira número 200. Os resíduos foram adicionados à misturas de duas formas: i) via úmida; ii) via seca. Na primeira, se colocaram em várias temperaturas de secagem (200°C, 300°C, 500°C, 800°C e seco ao ar) ao ligante asfáltico, já no segundo caso, realizando secagem a 175 °C para logo ser adicionado ao agregado miúdo. A interação ligante-lodos foi avaliada por meio dos ensaios de massa especifica, consistência e perda de massa ou variação RTFOT. Os lodos de ETA calcinados a 500°C apresentaram melhoria nas propriedades mecânicas e de adesividade. Já os lodos de ETE, secos à temperatura de aquecimento do ligante, e adicionados sobre o agregado miúdo apresentaram incrementos nas propriedades mecânicas. O estudo permitiu concluir que a utilização dos lodos de ETA ede ETE no concreto betuminoso para fins de construção rodoviária é viável quanto aos aspectos técnico e ambiental, sendo que pesquisas futuras serão importantes para um maior entendimento do comportamento dessas misturas e validação das conclusões a que se chegou. _______________________________________________________________________________________ ABSTRACT / Water Treatment Stations (WTS) and Sewage Treatment Stations (STS) generates alarge amount of sludge as products of their operations, these products are considered solid wasteby the ABNT 10004/2004 (Associação Brasileira de Normas Técnicas), and, without a propermanagement, the final disposal of waste can result harmful to the humanity and to theenvironment by cause pollution. So, that is an environmental issue to be avoided. This studyaimed to verify the usability of such waste in asphalt binders for hot asphalt concrete to knowif is this mixture could provide an improvement in its behavior, without taking into account, inthis initial phase, the direct costs of treatment and/or environmental liabilities. To facilitate theincorporation of WTS and STS sludge waste into the asphalt concrete was used a mechanicmill, in order to make the material pass through the sieve number 200. The residues were addedto the mixture by two ways: i) dry, and ii) wet. The first mixture was made subjecting thesamples to several high drying temperatures (200°C, 300°C, 500°C, 800°C and air dried) tothen add the asphalt binder; in the second case, the sludge was dried at 175 °C and added intothe fine aggregate. The sludge-ligand interaction was evaluated by the specific gravity tests, theconsistency and by the weight loss or variation RTFOT. The calcined WTS sludge (500 °C)showed improvement in mechanical and adhesion properties. While the STS sludge, dried atthe binder heating temperature, and added over the fine aggregate, showed increase only inmechanical properties. Therefore, the study conclude that the use of WTS and STS sludge’s inasphalt concrete, for road construction, is viable for technical and environmental aspects,however, future studies are needed to validate these results.
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unb.br:10482/16690 |
Date | 05 August 2014 |
Creators | Martinez, Juan Gabriel Bastidas |
Contributors | Lucena, Lêda Christiane de Fiqueirêdo Lopes, Carvalho, José Camapum de |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UnB, instname:Universidade de Brasília, instacron:UNB |
Rights | A concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições:Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data., info:eu-repo/semantics/openAccess |
Page generated in 0.0028 seconds