Return to search

Impacto de redes de distribuição com massiva conexão de geradores fotovoltaicos na estabilidade de tensão de longo-prazo em sistemas de potência

Submitted by Hellen Luz (hellencrisluz@gmail.com) on 2017-07-04T18:18:09Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_ImpactoRedesDistribuicao.pdf: 3740924 bytes, checksum: 3fc693c9e32013dada9cf9bf3be0bcd8 (MD5) / Approved for entry into archive by Irvana Coutinho (irvana@ufpa.br) on 2017-08-17T16:36:35Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_ImpactoRedesDistribuicao.pdf: 3740924 bytes, checksum: 3fc693c9e32013dada9cf9bf3be0bcd8 (MD5) / Made available in DSpace on 2017-08-17T16:36:35Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_ImpactoRedesDistribuicao.pdf: 3740924 bytes, checksum: 3fc693c9e32013dada9cf9bf3be0bcd8 (MD5)
Previous issue date: 2017-03-31 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Esta dissertação visa mostrar o impacto de geradores fotovoltaicos distribuídos, conectados nas redes de distribuição, na estabilidade de tensão de longo-prazo usando simulação completa no domínio do tempo. O efeito de diferentes níveis de penetração da geração fotovoltaica é investigado. Também são investigados diferentes modelos de redes de distribuição com geração distribuída: 1) Carga e GD representados por modelo ZIP e carga com potência ativa negativa do tipo corrente constante, respectivamente, na subestação (SE); 2) Carga e GD representados por modelo ZIP e equivalente dinâmico, respectivamente, na SE; 3) Carga e GD representados por modelo ZIP e modelo dinâmico, respectivamente, distribuídos ao longo de uma rede de distribuição de MT. Equipamentos como transformadores com comutação de tape sob carga (OLTC, do inglês, “On-Load Tap Changer”), limitadores de sobrecorrente de excitação (OEL, do inglês, “Overexcitation Limiter”), cargas estáticas e autotransformadores reguladores de tensão são levados em consideração nas análises, pois afetam significativamente a estabilidade de tensão de longo-prazo. As investigações são realizadas por meio do uso do software de análise de rede (ANAREDE) e do software de análise de transitórios eletromecânicos (ANATEM), desenvolvidos pelo Centro de Pesquisas de Energia Elétrica (CEPEL). A modelagem estática dos geradores fotovoltaicos é considerada como barras PQ, e a modelagem dinâmica é baseada no modelo PVD1 da WECC (Western Electricity Coordinating Council) implementada via Controle Definido pelo Usuário (CDU) no ANATEM. A proteção mandatória da geração fotovoltaica também é considerada. O sistema de potência estudado é uma junção de um sistema de transmissão de 11 barras com sistemas de distribuição da UKGDS (United Kingdom Generic Distribution System) de 76 barras cada. / This dissertation aims to show the impact of distributed photovoltaic generators connected to distribution networks on long term voltage stability using full time simulation. The effect of different penetration levels of photovoltaic generation is investigated. Different distribution network models considering distributed generation (DG) connections is also investigated: 1) Load and DG represented by ZIP model and negative active power loads, respectively, connected to the substation bus; 2) Load and DG represented by ZIP model and dynamic equivalent, respectively, connected to the substation bus; 3) Load and GD represented by ZIP model and dynamic model, respectively, distributed along a MV distribution network. Equipments such as On-Load Tap Changer (OLTC) transformers, Overexcitation Limiter (OEL), static loads and step voltage regulators are taken into account in the analyzes, since they significantly affect the long-term voltage stability. The investigations were conducted using both the power flow software ANAREDE and transient stability simulator ANATEM, developed by the Electrical Energy Research Center (CEPEL). For the purpose of power flow studies, photovoltaic generators are modeled as PQ buses with Q=0. The modelling of photovoltaic generators for dynamic studies is based on WECC (Western Electricity Coordinating Council) model, wich was inserted into file User Defined Controller (CDU) from ANATEM. The undervoltage protection of photovoltaic generator is also considered. The case studies were performed on a combined transmission and distribution model.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.ufpa.br:2011/8999
Date31 March 2017
CreatorsBARATA, Heitor Alves
ContributorsVIEIRA, João Paulo Abreu
PublisherUniversidade Federal do Pará, Programa de Pós-Graduação em Engenharia Elétrica, UFPA, Brasil, Instituto de Tecnologia
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFPA, instname:Universidade Federal do Pará, instacron:UFPA
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0158 seconds