Orientador: Roberto Feijo de Figueiredo, Gilberto De Martino Jannuzzi / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-23T18:40:13Z (GMT). No. of bitstreams: 1
Pires_MarcoRoberto_M.pdf: 4765440 bytes, checksum: 68b559c8fd33a90d801120162c2d3e21 (MD5)
Previous issue date: 1997 / Resumo: A desinfecção de água com radiação ultravioleta tem demonstrado ser uma alternativa à cloração. Os objetivos deste trabalho são: estudo da inativação dos microrganismos; análise' econômica do sistema de uv comparativamente a um sistema equivalente de desinfecção com cloro; e comparação do consumo de energia elétrica entre estes sistemas. Utilizou-se um reator (câmara de desinfecção), equipado com lâmpada de uv, operando no sistema de batelada. Os Microrganismos inativados foram E.coli, P.aeruginosa, A.hydrophila, E.faecalis e V.cholera. A análise econômica foi realizada em termos de implantação, operação e manutenção dos sistemas de cloro e uv com base nos preço de mercado. A comparação energética foi baseada na relação de volume de água desinfetada pelo consumo de energia elétrica entre os sistemas. A E.coli se mostrou o microrganismo de maior resistência inicial, mas a maior constante de inativação; o E.faecalis foi o mais resistente. O sistema de uv fornece água desinfetada a um custo de R$ 0,037 por habitante por ano. O consumo de energia elétrica entre os sistemas é equivalente para baixa dose de cloro. A radiação uv para desinfecção de água demonstra ser eficiente bactericida e compete economicamente com o cloro / Abstract: Ultraviolet radiation has been accepted as an altemative to chlorination for disinfection of water. The main subjects in this work can be summarized as follows: microorganism inactivation survey; comparative economical analysis between uv system and chlorine disinfection;comparative electrical energy consumption between them. A batch reactor, equipped with uv lamp, was used in the tests. E. coli, P.aeruginosa, A.hydrophila, E.faecalis, V.cholera, were the microorganisms employed for the study of inactivation. The economical analysis was accomplished based on capital costs, operation and maintenance of uv and chlorine system based on current market prices of components. The energetic analysis comparison was based on the volume ratio between disinfected water and electrical energy consumption of both the systems. The E.coli was the bacteria with the strongest initial resistance but the greatest inactivation constant. E.faecalis was the most resistant. The uv system provide disinfected water by R$ 0,037 per person per year. For low chlorine doses the electrical energy consumption between the two systems are equivalent. Finally, the work shows that uv radiation used for water disinfection is an important tool as an efficient bactericidal and that it competes economically with chlorination / Mestrado / Mestre em Planejamento de Sistemas Energéticos
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/265203 |
Date | 14 May 1997 |
Creators | Pires, Marco Roberto |
Contributors | UNIVERSIDADE ESTADUAL DE CAMPINAS, Jannuzzi, Gilberto de Martino, 1955-, Figueiredo, Roberto Feijó de, 1947-, Paterniani, José Euclides Stipp, Mendes, Carlos Gomes da Nave |
Publisher | [s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Mecânica, Programa de Pós-Graduação em Planejamento de Sistemas Energéticos |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | 85f. : il., application/pdf |
Source | reponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0023 seconds