Return to search

The Transient Behavior of an Ethane Dehydrogenation Furnace

This report deals with the mathematical model of the transient behaviour of an existing ethane dehydrogenation furnace which is composed of two main sections: a preheating convection section and a radiant-heated section. The correlation of pressure drop with time has been found from the available data. The fractional carbon deposition and the multiplier coefficient of a pressure drop equation have been determined by the direct search optimization technique of Hooke and Jeeves. An optimal policy for the cyclic operation of the furnace was determined by considering plant temperature profile and hydrocarbon/ steam ration as parameters for maximizing average ethylene produced per day. The effect of temperature profile on the distribution of carbon deposited along the reactor was also predicted and discussed. / Thesis / Master of Engineering (ME)

Identiferoai:union.ndltd.org:mcmaster.ca/oai:macsphere.mcmaster.ca:11375/18597
Date09 1900
CreatorsLi, Mou-Ching
ContributorsJohnson, A. I., Chemical Engineering
Source SetsMcMaster University
LanguageEnglish
Detected LanguageEnglish
TypeThesis

Page generated in 0.0023 seconds