Return to search

The impact of core temperature corrections on exercise-induced hypoxemia.

The primary purpose of this doctoral dissertation was to investigate the effect of body temperature responses at physiologically relevant sites during an incremental exercise test on the phenomenon of exercise-induced hypoxemia (EIH). This phenomenon has been considered as an important limitation to physical performance with a prevalence of ~50 % in trained male athletes, but described in both sexes, across the range of both age and physical fitness in more recent literature. Previously this phenomenon has been described as a decrement in both arterial oxygen partial pressure (PaO₂) and oxy-haemoglobin saturation (SaO₂or SpO₂) with, particularly important for PaO₂, a lack of or inappropriate correction made for the change in body temperature during intense exercise. The initial study of this thesis determined the thermal response within the body at physiologically relevant sites measured simultaneously during an incremental exercise test. The results demonstrated the inadequacy of rectal temperature as an indicator of the acute temperature changes occurring during an incremental exercise test due to its slow response rate and relative thermal inertia. Radial arterial blood and oesophageal temperatures were shown to behave almost identically during the exercise test, albeit with an offset of approximately 1.3ºC, and were considered much more appropriate and relevant indicators of thermal changes during exercise. As an extension of the initial work active muscle temperature (vastus lateralis) was measured during the exercise test, demonstrating a significantly lower resting temperature than the oft-reported “core” temperatures (rectal and oesophageal) as well as a significantly greater increase in temperature in comparison to all other measurement sites. Overall, the results of this first study indicated that the physiologically relevant temperatures measured at the oesophageal and muscle sites differed markedly to the outdated rectal temperature measurement site and should be used as measures of thermal response when evaluating oxygen loading (oesophageal) or unloading (active muscle). Utilising the definition of EIH as a decrease in PaO₂ of ≥ 10 mmHg, the effect of temperature correcting PaO₂ was evaluated in the second study. Arterial blood gases measured simultaneously to the temperature measurements during the incremental exercise test were adjusted for the temperature changes at each site (every 1ºC increase in temperature will increase a PaO₂ value by ~5 mmHg). Whilst uncorrected PaO₂ values indicated an almost 100% prevalence of EIH in this group, oesophageal temperature corrected PaO₂ values decreased this prevalence to ~50% while muscle temperature corrections resolved all cases of EIH and demonstrated an HYPEROXAEMIA (i.e. the reverse of the well-established phenomenon) in the majority of subjects. Further investigation of arterial oxygen content during the exercise test indicates that there is no disruption in the delivery of oxygen to the active muscles and therefore any performance decrement should be attributed to another mechanism. Whilst the phenomenon of EIH is determined by the definition applied and the use of temperature corrections in the case of PaO₂, its reproducibility in a test-retest situation had not previously been determined. Utilising a subset of previously tested subjects, the reproducibility of both temperature and PaO₂ were determined with results indicating that the blood gas response was highly reproducible, especially the minimum PaO₂ value noted during each exercise test. However, comparing a more statistically relevant definition of a change in PaO₂ of ± 2 standard deviations from the mean resting PaO₂ to the previous delimiter of 10 mmHg indicated a lesser reproducibility of the prevalence of EIH. In summary, this thesis exposes the inadequacies of previous research into EIH with regard to the expected reproducibility of the phenomenon and the need to correctly adjust PaO₂ values for exercise-induce hyperthermia as well as demonstrating the difference in thermal responses to acute exercise in physiologically significant areas of the body. Furthermore, previously described correlations between the change in PaO₂ and VO₂ max were not evident in the subjects tested within this thesis, nor was there any indication of a diffusion limitation based on reduced pulmonary capillary transit time (by association with VO₂ max) or pulmonary oedema (rebuked by a rapid return of PaO₂ to above resting levels following exercise cessation). / http://proxy.library.adelaide.edu.au/login?url= http://library.adelaide.edu.au/cgi-bin/Pwebrecon.cgi?BBID=1320633 / Thesis (Ph.D.) -- University of Adelaide, School of Medicine, 2008

Identiferoai:union.ndltd.org:ADTP/280287
Date January 2008
CreatorsShipp, Nicholas Jon
Source SetsAustraliasian Digital Theses Program
Detected LanguageEnglish

Page generated in 0.002 seconds