Return to search

Proposição de um método de detecção de FAI baseado nos componentes harmônicos de baixa frequência.

Submitted by Emanuel Varela Cardoso (emanuel.varela@ufcg.edu.br) on 2018-05-03T20:55:24Z
No. of bitstreams: 1
ÉRICA MANGUEIRA LIMA – DISSERTAÇÃO (PPGEE) 2016.pdf: 3788955 bytes, checksum: b005e5fd7bcddd43613e8d3de47b9e6c (MD5) / Made available in DSpace on 2018-05-03T20:55:25Z (GMT). No. of bitstreams: 1
ÉRICA MANGUEIRA LIMA – DISSERTAÇÃO (PPGEE) 2016.pdf: 3788955 bytes, checksum: b005e5fd7bcddd43613e8d3de47b9e6c (MD5)
Previous issue date: 2016-07-28 / Capes / Um método baseado nos harmônicos de baixa ordem para detecção de faltas de alta
impedância (FAI) é proposto nessa dissertação. A Short-Time Fourier Transform (STFT)
é empregada para extração dos principais componentes harmônicos da corrente de
fase proveniente de uma FAI, os quais são utilizados para identificar a ocorrência desse tipo de falta. Adicionalmente apresenta-se uma análise do tamanho e tipo da janela utilizada na transformada e sua adequação à aplicação. Para validação do método, duas bases de dados foram utilizadas: uma base contendo sinais simulados de FAI, chaveamento de bancos de capacitores e energização de linhas, e outra base contendo apenas registros oscilográficos reais de FAI. O método proposto é capaz de detectar a ocorrência de FAI em diferentes pontos do sistema, para diversos tipos de superfícies de solo e conseguiu também distinguir FAI dos outros distúrbios. Além disso, o método é tolerante aos ruídos que são próprios dos sinais reais, uma vez que se mostrou eficaz em todos os casos aos quais foram aplicados. / A method to detect high impedance faults (HIF) based on the low order harmonics is
proposed on this dissertation. The Short-Time Fourier Transform (STFT) is used to
extract the main harmonic components of the phase current, which are used to identify
a HIF occurrence. Additionally, the work presents an analysis on the window size and
type used in the STFT and its suitability for the application. The method is validated
using two databases: one containing HIF simulated signals mixed up with capacitor
banks switching and feeder energizing singals, and another containing only actual HIF
oscillograms. The proposed method is able to detect HIF occurring in various points
of the test-system, as well as HIF happening on different types of soil surfaces. It is
also able to distinguish HIF from the other tested disturbances. Futhermore, the
method tolerates typical noises present on real signals, since it proved to be effective
in all the applied cases.

Identiferoai:union.ndltd.org:IBICT/oai:localhost:riufcg/572
Date03 May 2018
CreatorsLIMA, Érica Mangueira.
ContributorsSOUZA, Benemar Alencar de., BRITO, Núbia Silva Dantas., NEVES, Washington Luiz Araújo., FERREIRA, Tarso Vilela.
PublisherUniversidade Federal de Campina Grande, PÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICA, UFCG, Brasil, Centro de Engenharia Elétrica e Informática - CEEI
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Biblioteca de Teses e Dissertações da UFCG, instname:Universidade Federal de Campina Grande, instacron:UFCG
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0017 seconds