A União Europeia ao adotar as diretivas: 2002/96/EC — WEEE e a 2002/95/EC — RoHS de modo a minimizar os resíduos equipamentos eletroeletrônicos (WEEE — do inglês: Waste Eletrical Electronic Equipment) e restringir as substancias nocivas (RoHS — do inglês: Restriction of Hazardous Substances) vem causando um grande impacto na rotina de controle de substancias perigosas, incluindo metais taco tóxicos, como chumbo, cadmio e cromo, em todos os materiais que são utilizados nesses equipamentos. Os componentes plásticos são os principais constituintes dos equipamentos eletrônicos e uma potencial fonte de metais taco tóxicos que são adicionados como estabilizantes, corantes e catalisadores. Como esses materiais plásticos são desenvolvidos de modo a serem resistentes a ataques químicos, eles são normalmente difíceis de serem dissolvidos. Sob esta motivação, neste trabalho foram desenvolvidos e otimizados métodos para a determinação de cadmio, chumbo e cromo utilizando a técnica de amostragem direta de sólidos por espectrometria de absorção atômica com forno de grafite. Em todos os procedimentos o foco principal foi a redução de tratamento das amostras, bem como o emprego de soluções padrão aquosas a fim de tornar os métodos mais simples e facilmente aplicáveis a rotina. O use de modificador químico, mistura de paládio e magnésia foi mandatório para estabilizar cadmio e chumbo. As determinações de cromo foram realizadas sem a adição de modificador químico. Calibração versus padrões aquosos Ode ser utilizada para a determinação dos três analitos. Nas determinações de chumbo e de cromo de modo a ter uma maior faixa linear de concentração usou-se o artificio de trabalhar com ou sem fluxo de gás na etapa de atomização. No caso da determinação de cadmio linhas analíticas (228,8 nm e 326,1 nm) com diferentes sensibilidades foram empregadas para ampliar a faixa linear do método. Os limites de detecção foram: 0,7 lig kg-1, 22 prg kg1 e 13 jig kg-1 para cadmio, chumbo e cromo, respectivamente. Materiais de referencia certificados foram utilizados para a validação dos métodos, não havendo diferença significativa entre os valores obtidos e os certificados. Oito amostras de resíduos de equipamentos eletroeletrônicos foram analisadas, estando todas em conformidade com as diretivas WEEE e RoHS. / By adopting the directives 2002/96/EC — WEEE (Waste Eletrical and Electronic Equipment) and 2002/95/EC — RoHS (Restriction of Hazardous Substances) the European Union will cause a great impact on the routine control of hazardous substances, including toxic trace metals, such as lead, cadmium and chromium, in all the materials that are used in this kind of equipment. Plastic components are among the main constituents of electronic equipment and a potential source of toxic trace metals, which are added as stabilizers, catalysts and/or colorant. As these plastic materials are designed to be resistant against chemical attack, they are usually very difficult to bring into solution. Because of that, methods have been developed and optimized in this work for the determination of cadmium, lead and chromium using direct solid sampling graphite furnace atomic absorption spectrometry. The primary aspects in all all method development have been reduction of sample treatment and the use of aqueous Standards for calibration in order to make methods simple and easily applicable in routine. The use of a mixture of palladium and magnesium as a chemical modifier was found to be mandatory for the determination of cadmium and lead, whereas no modifier was necessary for the determination of chromium. Calibration against aqueous standards could be used for all three analytes. In order to increase the linear working range for the determination of chromium and lead, the determination has been carried out with the internal gas flow turned off and on, respectively, during atomization. In the case of cadmium, the analytical lines at 228.8 nm and 326.1 nm, respectively, with significantly different sensitivities were used for that purpose. The detection limits were 0.7 p.g kg', 22 pig kg-1 and 13 !,ig kg-1 for cadmium, lead and chromium, respectively. Certified reference materials were used for validation of the methods, and there was no significant difference between the found and the certified values. Eight samples of residues of electronic equipment have been analyzed, and all of them were within the limits of the directives of WEEE and RoHS.
Identifer | oai:union.ndltd.org:IBICT/oai:lume56.ufrgs.br:10183/28310 |
Date | January 2010 |
Creators | Duarte, Álvaro Tavares |
Contributors | Vale, Maria Goreti Rodrigues |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | application/pdf |
Source | reponame:Biblioteca Digital de Teses e Dissertações da UFRGS, instname:Universidade Federal do Rio Grande do Sul, instacron:UFRGS |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0018 seconds