Return to search

Análise fractográfica e de resistência mecânica de duas marcas de placas de titânio em fraturas simuladas em corpo de hemimandíbulas de alumínio / Fractographic and mechanical analysis of two brands of titanium plates in simulated body fractures of aluminum hemimandibles

Orientadores: Marcelo Marotta Araújo, Roger William Fernandes Moreira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-23T00:56:38Z (GMT). No. of bitstreams: 1
Moura_AndrezzaLauriade_M.pdf: 4155630 bytes, checksum: 44572134d9e31084a7892cb0866a1d79 (MD5)
Previous issue date: 2013 / Resumo: O propósito no estudo foi avaliar comparativamente, através de teste de carregamento linear e análise fractográfica, duas marcas de material de fixação interna estável com dois métodos de fixação em fraturas simuladas em corpo de hemimandíbulas de alumínio. O trabalho foi dividido em dois grupos: Grupo I com duas estruturas de alumínio semelhantes à hemimandíbulas e fixação com duas placas de titânio de quatro furos do sistema 2,0mm, sendo uma placa na zona de compressão e outra zona de tensão, totalizando 20 placas de titânio; e grupo II, com duas estruturas de alumínio semelhantes à hemimandíbulas e fixação de uma placa de titânio de quatro furos do sistema 2,0mm na zona neutra de corpo de mandíbula, totalizando 10 placas de titânio. Testes de carregamento linear foram realizados por meio da máquina para ensaio universal mecânica Instron®, até a fratura do material. Após os testes, foram realizadas as análises fractográficas das superfícies de fratura dos materiais de fixação (grupos I e II) através de microscópio eletrônico de varredura FEI®, com o objetivo de analisar orientações, texturas e falhas dos materiais. Médias e desvio padrão das cargas e deslocamentos foram avaliados aplicando-se a Análise de Variância (ANOVA) two-way e teste de Tukey em nível de significância de 5%. Os resultados mostraram que o método de fixação com duas placas retas de quatro furos apresentou maior resistência à carga (p<0,01), quando comparado ao grupo de apenas uma placa de titânio na zona neutra mandibular. Ainda, a marca Traumec® apresentou maior resistência mecânica (p<0,01) quando utilizada no método com duas placas de fixação e a marca Tóride® (p<0,01) apresentou maior resistência as carga quando utilizada no método com apenas uma placa de fixação. A fractografia informou que todas as fraturas ocorreram por sobrecarga dúctil e micromecanismo alveolar / Abstract: The purpose of the study was to comparatively evaluate, through linear load test and fractographic analysis, two brands of stabel internal fixation in two methods of fixation in simulated body fractures in aluminium hemimandibules. The study was divided into two groups: Group I with two aluminum structures similar to hemimandibles for fixation of one 2,0mm miniplate in the compression zone and another one in tension zone, totaling 20 miniplates; and group II, with two aluminum structures similar to hemimandibles for fixation of one 2,0mm miniplate in the neutral zone of the mandible, totaling 10 miniplates. Mechanical tests were performed via mechanical universal testing machine Instron¿ until complete failure of the material. After the tests, fractography analysis of fractured surfaces were done in all materials (groups I and II) by a FEI¿ scanning electron microscopy, with the objective of analyzing orientation and textures of materials failures. Means and standard deviations of load and displacement were evaluated by applying the analysis of variance (ANOVA) two-way and the Tukey test at a significance level of 5%. The results showed that the method of fixation with two titanium plates with four holes showed higher resistance loads (p<0,01), when compared to only one titanium plate in the neutral zone of the mandible. Furthermore, the brand Traumec¿ showed higher mechanical strength (p<0,01) when used in the method with two fixing plates and the brand Toride¿ (p<0,01) showed a higher resistance to loads when used in the method with only one miniplate. The fractography reported that all fractures occurred in ductile overload and alveolar micromechanisms / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestra em Clínica Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/287837
Date06 April 2013
CreatorsMoura, Andrezza Lauria de, 1982-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Moreira, Roger William Fernandes, 1971-, Araujo, Marcelo Marotta, Gonçalves, Gabriela Mayrink, Barbosa, José Ricardo de Albergaria
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Clínica Odontológica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format86 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.003 seconds