Resistencia a compressão de paredes de alvenaria estrutural, com blocos assentados com argamassa plena e longitudinal

Orientador: Newton de Oliveira Pinto Junior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-04T00:14:58Z (GMT). No. of bitstreams: 1
Maas_CelsoRicardo_M.pdf: 5291856 bytes, checksum: eb48c5e46eeba69d2c7fae64e7014aea (MD5)
Previous issue date: 2004 / Resumo: Os dois objetivos principais deste trabalho são verificar e analisar a redução da carga de ruptura de paredes de alvenaria estrutural, quando os blocos são assentados com argamassa apenas nas suas paredinhas longitudinais (argamassa longitudinal). Estas verificações e análises se fazem necessárias porque a NBR 8798 (1985) ainda especifica a colocação de argamassa em todas as paredes dos blocos (argamassa plena), embora o que mais se tem observado nas nossas construções é a colocação de argamassa apenas nas paredinhas longitudinais. Além disso, essas verificações se tornam mais necessárias quando se sabe que esse tipo de assentamento é o mais usado nos países mais ricos e desenvolvidos do mundo. Para a determinação do valor dessa redução, bem como para melhor compreender a ruptura das paredes com esses dois tipos de assentamento, foram ensaiados corpos-de-prova de blocos, prismas e
paredes de 1,00 m de altura, na idade de 14 dias, com argamassa plena e longitudinal. Todos os ensaios foram feitos com blocos de concreto e com blocos cerâmicos. Finalizando, após evidenciar as deficiências dos atuais modelos de prismas, principalmente dos prismas com argamassa longitudinal, este trabalho tem como um último objetivo propor novos modelos de prismas para ensaios, em conformidade com os tipos de assentamento / Abstract: The two main aims of this work are to verify and analyze the reduction of the compressive strength of structural masonry walls, when the blocks are laid with mortar only in the outside faces of the block (face shell bedding). These verifications and analysis are important because, although the Brazilian code NBR 8798 (1985) still specifies that the entire block surface must be bonded (full mortar bedding), in Brazil the most used type of bedding is the face shell bedding. Besides, these verifications are important because we notice that the face shell bedding is used in the richest countries. In order to find the magnitude of this reduction and to understand the collapse of the two types of bedding, 14 days old specimens of blocks, prisms and wallettes of one meter height were tested, with face shell and full mortar bedding. All the tests were carried out with concrete and ceramic structural blocks. After realize the handicaps of the Brazilian
prisms, mainly that ones bonded whit face shell bedding, the last aim of this work is to propose a new model of prisms, to be used in laboratory tests / Mestrado / Edificações / Mestre em Engenharia Civil

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/257679
Date30 July 2004
CreatorsMaas, Celso Ricardo
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Pinto Junior, Newton de Oliveira, 1951-, Junior, Newton de Oliveira Pinto, Junior, Armando Lopes Moreno, Franco, Lui Sergio
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Civil, Arquitetura e Urbanismo
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format88p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0025 seconds