Continuous Concrete Beams Reinforced With CFRP Bars.

yes / This paper reports the testing of three continuously and two simply supported concrete beams reinforced with carbon fibre reinforced polymer (CFRP) bars. The amount of CFRP reinforcement in beams tested was the main parameter investigated. A continuous concrete beam reinforced with steel bars was also tested for comparison purposes. The ACI 440.1R-06 equations are validated against the beam test results.
Test results show that increasing the CFRP reinforcement ratio of the bottom layer of simply and continuously supported concrete beams is a key factor in enhancing the load capacity and controlling deflection. Continuous concrete beams reinforced with CFRP bars exhibited a remarkable wide crack over the middle support that significantly influenced their behaviour. The load capacity and deflection of CFRP simply supported concrete beams are reasonably predicted using the ACI 440.1R-06 equations. However, the potential capabilities of these equations for predicting the load capacity and deflection of continuous CFRP reinforced concrete beams have been adversely affected by the de-bonding of top CFRP bars from concrete.

Identiferoai:union.ndltd.org:BRADFORD/oai:bradscholars.brad.ac.uk:10454/7516
Date09 December 2015
CreatorsAshour, Ashraf, Habeeb, M.N.
Source SetsBradford Scholars
LanguageEnglish
Detected LanguageEnglish
TypeArticle, Accepted Manuscript
Rights© 2008 ICE. Reproduced in accordance with the publisher's self-archiving policy.

Page generated in 0.0021 seconds