Large structures exposed to the environment such as the collinear omni and large panel communication antennas in this research suffer damage from cyclic wind, rain, hail, ice load and impacts from birds and stones. Stresses from self-weight, ice loading and wind gusts will produce deformations of the structure that will lead to performance deterioration of the antenna. In order to avoid such a case, it is important to understand the static, dynamic and aerodynamic behavior of these structures and thus optimization can be achieved. In this research the current fluid-structure interaction methods are used to model, simulate and analyze these communication antennas in order to assess whether failure would occur under service loads. The FEA models developed are verified against analytical models and/or experiments. Different antenna configurations are compared based on their capacity to minimize vibration effects, stress-induced deformations and aerodynamic loading effects.