Return to search

Análise eletromiográfica e da força do músculo masseter em indivíduos com distintos padrões craniométricos / Electromyographic analysis and strength of the masseter muscle in individuals with distinct craniometric patterns

Orientador: Fausto Bérzin / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-19T14:48:48Z (GMT). No. of bitstreams: 1
Dressano_Danilo_M.pdf: 1270747 bytes, checksum: 4699fc2bda742e1bb38aee6d188ed0a2 (MD5)
Previous issue date: 2012 / Resumo: Eletromiografia de superfície é uma ferramenta que auxilia um estudo aprofundado sobre patologias em áreas que trabalham com o movimento muscular. Muitos estudos relatam que indivíduos com padrões craniométricos distintos podem apresentar diferenças no padrão do movimento mandibular. Foram analisados 31 sujeitos, divididos em três grupos (09 dolicocéfalos, 14 mesocéfalos e 08 braquicéfalos), gêneros masculino e feminino, entre 18 e 28 anos de idade, Classe I de Angle, saudáveis, não apresentando disfunção temporomandibular, bruxismo e/ou apertamento dental e sem agenesia. As dimensões cranianas foram tomadas com o compasso antropométrico de Willis. Para a investigação da atividade elétrica foi realizada eletromiografia de superfície no músculo masseter e um transdutor de mordida posicionado em todos os dentes a fim de captar o biofeedback das forças oclusais. Todos os voluntários foram orientados a aplicar e manter uma força oclusal de 20 Kgf por 5 segundos. Para análise da amplitude média do sinal eletromiográfico e da força muscular foi calculado o valor do Root Means Square (RMS). Para cada grupo foram relacionados os valores do RMS no movimento de contração voluntária e aplicação de força oclusal, e os valores no movimento de mastigação comparados. Com os dados obtidos foi possível concluir que existem diferenças significativas em indivíduos classe I de Angle e com distintos padrões craniométricos. Nesse estudo o grupo dolicocéfalo foi capaz de exercer e sustentar uma força oclusal maior que os outros dois grupos, porém com um valor de RMS mais elevado, sugerindo maior esforço muscular. O grupo braquicéfalo exerceu e manteve uma força oclusal pouco abaixo do estabelecido, porém com um valor de RMS médio próximo ao grupo mesocéfalo, que exerceu menor força. Isso pode sugerir um melhor aproveitamento da energia muscular e uma maior estabilidade da força muscular durante o movimento de contração voluntária submáxima no grupo braquicéfalo / Abstract: Surface electromyography is a hardware that supports a deeper study about pathologies in areas that works with the muscular movement. Several studies reports that subjects with distinct craniometrical patterns may exhibit different movement functions. Thirty one subjects were analysed, divided in three groups (09 dolichocephalics, 14 mesocephalics and 08 brachicephalics), genders masculine and feminine, between 18 and 28 years old, Angle's class I, healthy, no presence of temporomandibular disfunction, bruxism, clenching or dental agenesis. The cranial dimensions were taken with the anthropometrical Willis's compass. To the investigation was performed surface electromyography in the masseter muscle and a bite transducer positioned in all teeth to get the biofeedback of the oclusal forces. All volunteers were instructed to implement and maintain an oclusal force of 20 Kgf for 5 seconds. To analyze the mean amplitude of electromyographic signal and the muscular force was calculated the Root Mean Square (RMS) value. For each group were related the RMS value in the volunteer muscular contraction movement and implement of oclusal force and the values of the mastication movements were compared. With the data it was concluded that there is significant differences in individuals Angle's class I with different craniometrical patterns. In this study the dolichocephalic group was capable to prosecute and maintain a superior oclusal force than the two other groups, however the RMS value plus elevated, suggesting a higher muscular effort. The brachicephalic group prosecuted and maintained a little below oclusal force value than the instructed, however with the mean RMS value closer to the mesocephalic group, who exerted less force. It may suggest a better use of the muscular energy and higher muscular force stability during the submaximal voluntary contraction in the brachicephalic group / Mestrado / Anatomia / Mestre em Biologia Buco-Dental

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/288824
Date19 August 2018
CreatorsDressano, Danilo, 1983-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Bérzin, Fausto, 1940-, Kroll, Claudia Duarte, Gavião, Maria Beatriz Duarte
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Biologia Buco-Dental
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format41 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0021 seconds