Return to search

Desenvolvimento de placas para fixação interna rígida : estudo da resistência a compressão em fraturas simuladas de côndilo da mandíbula / Development of plates for internal fixation : study of resistance to compression fractures of mandibular condyle simulated

Orientador: Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-23T15:57:19Z (GMT). No. of bitstreams: 1
CelegattiFilho_TorideSebastiao_M.pdf: 4195192 bytes, checksum: e279d02d5c5aabef9927997e90717129 (MD5)
Previous issue date: 2013 / Resumo: O propósito neste estudo foi desenvolver placas em forma de Y com espessuras de 0,6, 1,0 e 1,5 mm para ser usadas em fratura de colo de côndilo da mandíbula e submetê-las ao ensaio de resistência mecânica de compressão. Fo-ram desenvolvidas 10 placas em Y para cada espessura, contendo 8 furos. As placas foram confeccionadas de acordo com projeto idealizado pelo autor e fabricado pela empresa Toride Indústria e Comércio Ltda., Mogi Mirim, SP, Brasil. As placas foram confeccionadas com titânio comercialmente puro (grau ll), conforme norma ASTM F-67. Os processos para desenvolvimento das placas foram feitos em programa de desenho mecânico Solid Works. A confecção das placas seguiu a metodologia de fabricação já existente na empresa, compreendendo processo de usinagem em equipamento modelo Discovery Romi de 4 eixos, o qual mantém precisão e controle dimensional com tolerância de ± 0,10 mm. Foram também confeccionadas 30 hemi-mandíbulas do lado esquerdo, com resina de poliuretano rígido de densidade 40 a 50 PCF onde as placas foram fixadas para conter fratura simulada da cabeça do côndilo. O teste de carregamento foi executado na máquina para ensaio universal Instron, modelo 4411, aplicando carga na posição médio-lateral e ântero-posterior na cabeça do côndilo. ANOVA com 2 fatores e teste de Tukey com 5% de significância foram aplicados nos resultados. Quando a carga foi aplicada no sentido médio-lateral, a placa de maior espessura (1,5 mm) obteve a maior resistência, mas sem diferença estatística entre os deslocamentos de 5,0 e 10,0 mm. No sentido ântero-posterior, a placa com maior resistência foi a de menor espessura, seguida pela de maior espessura. Pode-se concluir que: 1 - No sentido médio-lateral, os maiores valores de resistência foram observados no deslocamento de 15 mm, exceto para as placas 0,6 e 1,5 mm com valores similares em 10 e 20 mm respectivamente; 2 - A placa com espessura de 1,5 mm foi a única que apresentou maior valor médio em todos os deslocamentos; 3 - No sentido ântero-posterior, os maiores valores de resistência foram vistos no deslocamento de 15 mm e os menores em 5 mm para todas as espessuras de placas; 4 - A placa com espessura de 0,6 mm foi a que apresentou maiores valores em todos os deslocamentos e 5 - No sentido ântero-posterior, o carregamento de 20 mm não foi alcançado / Abstract: The purpose of this study was to develop a Y plate with thicknesses of 0.6, 1.0 and 1.5 mm for use in condylar mandible fracture and submit them to the me-chanical strength testing Compression. For this study 30 plates were used for surgical containment internal, Y geometry and holes 8, 10 plates with a thickness of 0.6 10 mm plates with 1.0 mm thickness and 10 plates with thickness of 1.5 mm. This model plate was designed by the author and manufactured by Toride Industry e Comercio Ltda., Mogi Mirim, Brazil. The plates were made from commercially pure titanium (grade II), according to ASTM F-67. The processes for developing the plates were made in program Solid Works mechanical design engineering company by Toride, following the procedures of the project. The making of the plates followed the methodology in an existing manufacturing company, including process equipment machining model Romi Discovery of 04 axes, which keeps ac-curacy and dimensional control with a tolerance of ± 0.10 mm, required by the quality system of the company Toride. Were prepared hemi-jaws 30 on the left side with hard polyurethane resin density 40-50 PCF where the plates were fixed. The load test was run on the test equipment universal Servohidráulico Instron Model 4411 (Instron Corp., Norwood, MA.), and will have to evaluate the strength of plates attached Hemi-mandibles applying the force in mid-lateral position, and the force applied at Antero-posterior position, were predetermined three shifts, ob-taining values of average load in the three, Statistical analysis of variance by ANOVA used 02 factors, the Tukey test at 5% significance level was applied. When the load was applied in the medial-lateral plate of greater thickness (1.5 mm) gave the highest strength, but no statistical difference in displacement of 5.0 and 10.0 mm. Antero-posterior direction on the plate was the biggest strength of thinner, following the greater thickness. It can be concluded that: 1 - In the medial - lateral direction, the highest values of resistance were observed in the displacement of 15 mm, except for the 0.6 and 1.5 mm plates with similar values in 10 and 20 mm respectively; 2 - A plate with thickness of 1.5 mm was the one with the highest average value on all shifts; 3 - In the antero-posterior direction, the highest values of resistance were seen in the displacement of 15 mm and 5 mm in the minors for all thicknesses of plates; 4 - A plate with thickness of 0.6 mm showed the highest values in all shifts and; 5 - In the antero-posterior direction, the loading of 20 mm was not achieved / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/290054
Date03 July 2013
CreatorsCelegatti Filho, Tóride Sebastião, 1966-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Consani, Simonides, 1939-, Guiraldo, Ricardo Danil, Moreira, Roger William Fernandes
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Materiais Dentários
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format69 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0027 seconds