Orientador: José Gilberto Dalfré Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-23T10:42:36Z (GMT). No. of bitstreams: 1
Aquino_GenivaldoAlcantarade_M.pdf: 13175596 bytes, checksum: 7fcf5fba9c6608250faca3ec3bc0b3a1 (MD5)
Previous issue date: 2013 / Resumo: A presença de ar aprisionado no interior da tubulação de água pode levar a operação irregular ou, até mesmo, danos aos sistemas de abastecimento de água e seus componentes. A presença de ar aprisionado pode ocorrer durante o funcionamento regular, ou quando os sistemas de bombeamento estão em operação. A formação de bolsões de ar pode produzir o fenômeno do golpe de aríete, instabilidade e perda de pressão nas redes de abastecimento de água. A fim de evitar a sua formação, todo o ar preso deve ser removido, seja através de remoção mecânica por válvulas de ar ou remoção hidráulica (deslocamento do ar com o escoamento). No Brasil, as indústrias de válvulas de ar, muitas vezes, não possuem caracterização adequada destas válvulas, ou seja, as características das válvulas (geométrica, mecânica, hidráulica e dinâmica) devem ser determinadas. Este trabalho teve como objetivo desenvolver uma bancada de testes para ensaios de válvulas ventosas e testar estas válvulas em ensaios dinâmicos, caracterizando-as. A bancada experimental mostrou-se eficiente para os ensaios de válvulas ventosas. Os resultados dos ensaios dinâmicos das válvulas podem contribuir para que um sistema hidráulico passe a operar de uma maneira segura, diminuindo os riscos associados aos eventuais fenômenos transitórios, além de servir como referência para futuros projetos de sistemas de abastecimento. Foi confirmado que, além das curvas características em condição estática, as curvas características em condição dinâmica também devem ser analisadas, pois apresentam características de funcionamento distinto / Abstract: The presence of trapped air inside the water pipelines can lead to irregular operation or even damage the water supply systems and their components. The presence of trapped air can occur during regular operation, or while pumping systems are in operation. The formation of air pockets can produce the phenomenon of water hammer, instability and loss of pressure in water supply systems. In order to prevent its formation, all the trapped air must be removed, either by mechanical removal through air valves or hydraulic removal (by displacement of the air flow). In Brazil, industries of air valves, many times, do not possess proper characterizations of the air valves. To achieve this, all the characteristics of the valve (geometric, mechanic, hydraulic and dynamic) should be determined. This study developed a test bench for testing the air valves, characterizing them. The bench was efficient for testing and the results of the dynamic tests can contribute to operate a hydraulic system in a safe manner, reducing the risks associated with possible transient phenomena, besides serving as a reference for future projects of water supply systems. It was confirmed that, in addition to the characteristic curves in static condition, the characteristic curves in dynamic condition must also be considered, since they show different operating characteristics / Mestrado / Recursos Hidricos, Energeticos e Ambientais / Mestre em Engenharia Civil
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/258602 |
Date | 23 August 2018 |
Creators | Aquino, Genivaldo Alcântara de |
Contributors | UNIVERSIDADE ESTADUAL DE CAMPINAS, Dalfré Filho, José Gilberto, 1976-, Filho, Jose Gilberto Dalfre, Koelle, Edmundo, Mambretti, Stefano |
Publisher | [s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Civil, Arquitetura e Urbanismo, Programa de Pós-Graduação em Engenharia Civil |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | 138 p. : il., application/pdf |
Source | reponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0026 seconds