The increased moisture of the building materials causes the change of its mechanical and physical characteristic. In particular the high amount of loose water in construction shorten the lifetime of the building, is harmful to human beings due to biotic factors and increase the economic expenses of usage of the building. Apart from the costs of rehabilitation the loose water deteriorates the thermal insulative ability (thermal conductivity coefficient ) of perimeter masonry as well. The moisture gets into masonry not only through its deffects but also due to many different reasons. In order to improve the utility value of the buildings we have to deal with the rehabilitation of damp masonry with view to all possible causes. Only the properly working damp proofing ensures the protection against the water leaking from the subfoundation of the building. One of the direct techniques which have undergone rapid progress in last few years is the injection procedure. With use of experimental methods in my dissertation I deal with evaluation of two injection compounds used in Czech Republic and with its impact on the characteristics of the mortar. With the modern hollow bricks (system THERM) it is possible to create horizontal infusion into the lateral mortar grooves in future.