Submitted by Edileide Reis (leyde-landy@hotmail.com) on 2014-09-24T11:36:14Z
No. of bitstreams: 1
ADERVAL BARROS DA SILVA.pdf: 908094 bytes, checksum: 131bc077df65b89fbddfba25757cf151 (MD5) / Approved for entry into archive by Jose Neves (neves@ufba.br) on 2016-06-03T21:19:46Z (GMT) No. of bitstreams: 1
ADERVAL BARROS DA SILVA.pdf: 908094 bytes, checksum: 131bc077df65b89fbddfba25757cf151 (MD5) / Made available in DSpace on 2016-06-03T21:19:46Z (GMT). No. of bitstreams: 1
ADERVAL BARROS DA SILVA.pdf: 908094 bytes, checksum: 131bc077df65b89fbddfba25757cf151 (MD5) / Neste trabalho foram medidas as composições isotópicas de amostras de água dos reservatórios de França e de São José do Jacuípe, localizados na sub-bacia do Rio Jacuípe, amostradas em outubro (2003); junho (2004); setembro (2004) e março (2005) em vários pontos das barragens. Além das razões \O^{18}/\O^{16}\ e D/H, determinadas no Laboratório de Física Nuclear da UFBa, também foram medidos, \emph{in situ}, os parâmetros físico-químicos de condutividade elétrica, sólidos totais dissolvidos, oxigênio dissolvido, temperatura e pH. O comportamento das composições isotópicas nos vários pontos amostrados permitiu selecionar um grupo representativo da composição isotópica das barragens, separados dos que apresentaram indicação de interferência local de outras fontes de água. A partir desses pontos representativos foram construidas as linhas de evaporação nos diagramas $\delta$\O^{18} X $\delta$D características dos reservatórios. A partir da equação de Rayleigh para a evolução isotópica de um corpo de água em evaporação, incluindo além do fracionamento isotópico de equilíbrio líquido/vapor, o fracionamento cinético em função da umidade relativa do ar, foram calculadas as linhas de evaporação para uma faixa de valores em torno das condições médias de temperatura e umidade relativa do ar características da região. A comparação entre a simulação e os valores observados para a composição isotópica da água nas barragens levou a caracterização, para uma temperatura média de 25^{0}C para a região, de uma umidade relativa média de 80% acima da barragem de França e 85% acima da barragem de São José do Jacuípe. Baseado no intervalo entre as amostragens do início de junho e meados de setembro de 2004, período em que a quantidade de precipitação na região foi muito pequena, foi calculado a fração do volume evaporado no reservatório de França, correspondente à variação da composição isotópica nesse período, conduzindo a uma evaporação de 10% do volume acumulado no reservatórios de França no início do período considerado. Este resultado foi comparado com os dados hidrológicos disponiveis da ANA e SRH para a região, que apesar da grande incerteza de alguns deles conduzem a um balanço hídrico comparável, mostrando que o acompanhamento isotópico poderá contribuir de uma maneira significativa para a quantificação da evaporação. / Abstract
This work presents an isotope based characterization of Fran¸ca and S˜ao Jos´e do Jacu´ıpe
reservoirs localized on the Jacu´ıpe River, tributary of the Paragua¸cu River Basin. Thirteen
points of the reservoirs were sampled in four occasions, october/2003, june/2004, september/2004
and march 2005. In addition to the measurements of the isotopic ratios 18O/16O
and 2H/1H (D/H), it was also measured the physico-chemical parameters of electrical conductivity,
total dissolved salts, dissolved oxygen, temperature and pH. The pattern of the
isotopic composition of the several sampled points allowed to separate those representative
of the isotopic composition of each reservoir from others with interference of local sources
of water. From these points, plotted in a 18O versus D diagram, was obtained the evaporation
line characteristic of each reservoir. Using the Rayleigh equation for the isotopic
evolution of an evaporating water body including the kinectic fractionation dependent on
the atmospheric humidity, besides the equilibrium isotopic fractionation dependent on the
temperature, it was simulated the evaporation line for a set of values of temperature and
humidity around the typical ones for the region. The comparison between the simulation
and the observed data led to the fit, for a temperature of 250C, of a humidity of 80% above
the Fran¸ca reservoir and 85% above the S˜ao Jos´e do Jacu´ıpe reservoir. Taking the interval
between the second and third sampling, when the amount of precipitation in the region
was very small, and based on the variation of isotopic composition of the Fran¸ca reservoir
observed in this interval, it was calculated the fraction of the volume evaporated, leading
to a evaporation of around 10% of volume in Fran¸ca. This result was compared with data
from ANA and SRH agencies for the region that, even though with large uncertainties, lead
to a comparable water balance for the period, showing that the isotopic monitoring can
contribute to the quantification of the evaporation of reservoirs in our region.
Keywords: 1. stable isotopes, 2. oxygen-18, 3. deuterium, 4. water balance, 5. isotopic enrichment,
6. reservoir evaporation.
Identifer | oai:union.ndltd.org:IBICT/oai:192.168.11:11:ri/19367 |
Date | January 2007 |
Creators | Silva, Aderval Barros da |
Contributors | Azevedo, Antônio Expedito Gomes de, Oliveira, Iara Brandão de, Zucchi, Maria do Rosário, Azevedo, Antônio Expedito Gomes de |
Publisher | Universidade Federal da Bahia. Instituto de Geociências, Programa de Pós-Graduação em Geofísica (PGEOF), UFBA, brasil |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UFBA, instname:Universidade Federal da Bahia, instacron:UFBA |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0019 seconds