The master thesis deals with design of a switched DC power supply with output parameters of 30 V 60 A. The power supply uses the connection of two single switch forward converters with opposite phase. The topology was chosen based on a comparison of specific schematics in the first part. The body of the thesis is covered in chapter which deals with design and analysis of power circuits of the converter. The chapter describes detailed design of pulse transformers, dimensioning of semiconductors and cooling system of the converter. For lower power losses, the system of synchronous rectifying is chosen at the output of the circuit. The regulation of the output is based on cascade structure with a superior voltage and dependent current loop. Appropriate over current protection is provided by sensing the output current and using current transformers for primary current measure.