Return to search

Colunas mistas esbeltas de aço preenchidas com concreto de alta resistencia em temperatura ambiente e em situação de incendio / Mixed slender steel columns filled with high strenght concrete in room temperature and fire situation

Orientador: Armando Lopes Moreno Junior / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-13T04:09:02Z (GMT). No. of bitstreams: 1
LeiteJunior_GeraldoSilveira_D.pdf: 5865663 bytes, checksum: d49ee862fe97f6a26434a033e8947468 (MD5)
Previous issue date: 2009 / Resumo: Neste trabalho, foi investigado em laboratório o efeito do fogo em colunas esbeltas de aço sem preenchimento e preenchidas com concreto de alta resistência que foram submetidas a três diferentes níveis de carga (30%, 50% e 70%). O nível de carga é a razão entre a carga axial a ser aplicada em situação de incêndio e a carga última obtida no ensaio da coluna à temperatura ambiente. Assim sendo, colunas esbeltas de aço sem preenchimento e preenchidas com concreto de alta resistência também foram investigadas à temperatura ambiente, uma vez que os resultados obtidos nessa situação serviram de referência para o estabelecimento das cargas axiais que foram aplicadas em situação de incêndio. Ao todo, foram investigadas 32 colunas esbeltas, sendo 4 sem preenchimento e 4 preenchidas com concreto de alta resistência em temperatura ambiente. Além dessas colunas, 12 foram ensaiadas sem preenchimento e 12 preenchidas com concreto de alta resistência em situação de incêndio. Os valores experimentais de carga última obtidos com as colunas de aço sem preenchimento e preenchidas com concreto de alta resistência à temperatura ambiente e em situação de incêndio foram comparados a aqueles determinados a partir da formulação proposta respectivamente pelo EUROCODE 3 (prEN 1993-1-1:2001), EUROCODE 4 (prEN1994-1-1:2003), EUROCODE 3 (prEN 1993-1-2:2002) e pelo EUROCODE 4 (prEN1994-1-2:2002), além de outras propostas de pesquisadores que foram encontradas na escassa literatura sobre o assunto. Como parte numérica, os resultados obtidos para as colunas mistas em situação de incêndio foram comparados a aqueles determinados por meio da utilização de dois softwares, que foram o SuperTempCalc e o PotFire. Ao final, observou-se que o preenchimento das colunas esbeltas de aço com concreto de alta resistência, propiciou melhorias significativas no tempo de resistência ao fogo dessas colunas, porém, comprovou-se que, de forma geral, somente as colunas em situação de incêndio que atingiram o tempo mínimo de resistência ao fogo, estipulado tanto no EUROCODE 4 (prEN 1994-1-2:2002), quanto na NBR 14432 (2000) em 30 minutos, foram as que apresentaram os resultados mais satisfatórios. / Abstract: In this work, it was investigated in laboratory the effect of fire in slender steel columns unfilled and filled with high strength concrete submitted to three different levels of axial load (30%, 50% and 70%), which is the relation between the axial load to be applied in fire situation and the ultimate load obtained in the column test to room temperature. So, slender steel columns unfilled and filled with high strength concrete were also investigated to room temperature, once the results obtained in this situation have served of reference to the establishment of axial loads applied in fire situation. Altogether 32 slender columns were tested, being 4 unfilled and 4 filled with high strength concrete in room temperature. Besides these columns, 12 were tested filled with high strength concrete in fire situation and 12 unfilled. The experimental values of ultimate load obtained with steel columns unfilled and filled with high strength concrete to room temperature and in fire situation were compared to those determinated from the formulation proposed by EUROCODE 3 (prEN 1993-1-1:2001), EUROCODE 4 (prEN1994-1-1:2003), EUROCODE 3 (prEN 1993-1-2:2002) and EUROCODE 4 (prEN1994-1-2:2002), besides others researchers' proposals found in scarce literature about the subject. As a numeric part, the results obtained for mixed columns in fire situation were compared to those determinated by means of using two softwares, the SuperTempCalc and the PotFire. At the end, it was observed that the filling of slender steel columns with high strength concrete have provided significant improvement in the time of resistance to fire in these columns, but it was proved that, in general, only the columns in fire situation which reached the minimum time to fire resistance, stipulated in EUROCODE 4 (prEN 1994-1-2:2002), as in NBR 14432 (2000) in 30 minutes, were the ones that have presented the most satisfactory results. / Doutorado / Estruturas / Doutor em Engenharia Civil

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/258263
Date02 June 2009
CreatorsLeite Junior, Geraldo Silveira
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Moreno Junior, Armando Lopes, 1964-, Junior, Armando Lopes Moreno, Mascia, Nilson Tadeu, Silva, Maria Cecília Amorim Teixeira da, Munaiar Neto, Jorge, Filho, Luiz Carlos Pinto da Silva
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Civil, Arquitetura e Urbanismo, Programa de Pós-Graduação em Engenharia Civil
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format261 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0023 seconds