Welded connections at high-strength steel hollow section joints

The calculation of the loadbearing capacity of hollow section joints using the design formulas according to EN 1993-1-8 assumes full-strength welded connections if the non-linear stress distribution over the circumference is not covered by calculation. Sufficient ductility in the connections ensures a plastic redistribution capacity within each joint. In the case of hollow section structures made of high-strength steels, it becomes more difficult to meet the requirement for full-strength welds as the yield strength of the base material increases.

This article begins with a summary of the current rules for the design and execution of welded hollow section joints. The softening behaviour of high-strength steels and the loadbearing capacity of welded connections with local softening in the HAZ are then discussed. That is followed by the presentation of the results from the AiF-FOSTA research project P1020 regarding the influence of manufacturing parameters on the properties of welded connections and the HAZ. The experimental test programme for single-sided welded T-connections and the parameter studies within the research project P1453 are also described. Finally, a design approach is presented to account for HAZ failure and hybrid failure modes of hollow section connections.

Identiferoai:union.ndltd.org:DRESDEN/oai:qucosa:de:qucosa:90405
Date08 April 2024
CreatorsStroetmann, Richard, Kästner, Thoralf, Rust, Brian, Schmidt, Jan
PublisherErnst & Sohn
Source SetsHochschulschriftenserver (HSSS) der SLUB Dresden
LanguageEnglish
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, doc-type:article, info:eu-repo/semantics/article, doc-type:Text
Rightsinfo:eu-repo/semantics/openAccess
Relation1867-0539, 10.1002/stco.202100036

Page generated in 0.0024 seconds