The aim of this thesis is to prove a necessity of re-certification after window seal change. A euro window was made and it was used five types of seals. All of this seals were measured on air-permeability and watertigthness. A differences in air-permeability among seals were measured. It was also determined huge impact on watertighness with correct sealing of head flashing with plastic ending. The watertightness is much better when is end of head flashing with plastic ending sealed with silicone sealant. The conclusion is necessity of re-certification of window after seal change. Because this step has significant effect on final watertigthness and air-permeability of window.
Identifer | oai:union.ndltd.org:nusl.cz/oai:invenio.nusl.cz:428387 |
Date | January 2019 |
Creators | Hanzlík, Miroslav |
Source Sets | Czech ETDs |
Language | Czech |
Detected Language | English |
Type | info:eu-repo/semantics/masterThesis |
Rights | info:eu-repo/semantics/restrictedAccess |
Page generated in 0.0021 seconds