Return to search

Influência da segmentação e reconstrução de imagem na capacidade de diagnóstico da Tomografia Computadorizada de Feixe Cônico utilizando softwares com plataforma DICOM / The impact on diagnostic yield of dental segmentation and reconstruction using DICOM compatible software systems

Orientador: Francisco Haiter Neto / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-22T03:09:52Z (GMT). No. of bitstreams: 1
Melo_SauloLeonardoSousa_D.pdf: 2218152 bytes, checksum: 8cf34e11fc626dc8ea70836a2401feb5 (MD5)
Previous issue date: 2013 / Resumo: As fraturas radiculares apresentam diagnóstico clínico limitado visto que os sinais e sintomas apresentados pelo paciente são inespecíficos. Como a maioria das fraturas leva à extração do dente, torna-se necessário um diagnóstico mais preciso. A tomografia computadorizada de feixe cônico (TCFC) é considerada um método de diagnóstico avançado na aquisição de imagens livres de sobreposições das estruturas orofaciais. Geralmente as imagens por TCFC são segmentadas e reconstruídas em DICOM, visto que existe uma grande disponibilidade de softwares que utilizam este formato. Por se tratar de uma tecnologia relativamente recente, e que rapidamente vem se difundindo no meio odontológico, o presente estudo avaliou a influência do uso de softwares com plataforma DICOM na capacidade de diagnóstico das imagens por TCFC na detecção de fraturas radiculares verticais induzidas experimentalmente. Foram utilizados cento e noventa dentes unirradiculares humanos, com os condutos radiculares modelados, divididos em 3 grupos, de acordo com a condição do canal radicular: não-preenchido (NP); preenchido com guta-percha (GP); e parcialmente preenchido por núcleo metálico fundido (NM). Metade dos elementos de cada grupo foi fraturada artificialmente, com posterior reposicionamento dos fragmentos. Um cone de guta-percha bem adaptado foi inserido no canal dos dentes do grupo GP e núcleos metálicos fundidos foram confeccionados nos dentes do grupo NM. Todos os dentes foram posicionados em um crânio seco humano e escaneados em um aparelho de TCFC, conforme o protocolo de escaneamento da maxila utilizando voxel de 0.2 mm. As imagens foram salvas no formato original (.xstd), assim como segmentadas e reconstruídas em DICOM. As imagens originais foram analisadas no software do tomógrafo (Xoran) e as imagens DICOM nos softwares Dolphin, InVivo e KDIS3D. Foram selecionados três cirurgiões-dentistas radiologistas para avaliar as imagens quanto à ausência ou presença de fratura radicular, em uma escala de 5 pontos. Sensibilidade, especificidade, acurácia e área sob a curva ROC foram calculadas. A influência do material intracanal e do software utilizado foi verificada por meio do modelo de análise de variância (ANOVA) e comparações pareadas realizadas por meio do teste de Tukey, considerando-se um nível de significância de 5%. Não houve diferença estatisticamente significativa entre os softwares quando a mesma condição era apresentada. No entanto, quando comparada com os grupos NP e GP, a acurácia de diagnóstico foi menor no grupo NM em qualquer software utilizado (p < 0,05). Concluiu-se que o diagnóstico de fratura radicular não depende do software, podendo o profissional utilizar o de sua preferência. Todavia, a presença de núcleo metálico diminui a possibilidade de um diagnóstico correto / Abstract: Root fractures have limited clinical diagnosis because signs and symptoms are nonspecific. However, an accurate diagnosis is necessary as most fractures result in tooth extraction. In the last years, Cone beam computed tomography (CBCT) technology has been considered an advanced procedure to obtain images free from overlaps of maxillofacial structures. Usually CBCT images are exported in DICOM format, since there is a wide availability of software that uses this format. Since it is a relatively new technology and that is spreading quickly among dental routine, this study evaluated the influence of segmentation and reconstruction of CBCT images in the diagnostic ability of experimentally induced vertical root fractures using software with DICOM platform. One hundred and ninety extracted, single-rooted, human teeth were included in the study. Each tooth had its root canal prepared, randomly coded and divided into 3 groups according to the pulp canal status: unrestored (UR); filled with gutta-percha (GP); and restored with a metallic custom post (Post). One-half of the samples of each group were artificially fractured and segments repositioned. The experimental sample was artificially fractured. A well-fitting gutta-percha cone was placed into the canal of GP group teeth, and a well-fitting post casted was placed into the canal of Post group ones. All teeth were placed in an empty maxillary anterior socket of a dentate dry human skull and scanned on a CBCT device according to the protocol recommended by the manufacturer for a 0.2-mm voxel resolution (8-cm FOV, 120kVp, 8mA, 40-sec). The images were converted to DICOM files, imported, reconstructed and analyzed into Dolphin, InVivo and KDIS3D software. The original images were also reconstructed and evaluated using the software of the scanner (Xoran). The images were coded and shown to three previously calibrated oral radiologist observers, who performed a dynamic evaluation. The observer's evaluation of the presence of root fracture was scored using a 5-point confidence rating scale. Sensitivity, specificity, and accuracy were calculated, and from the values found, ROC curves were constructed to assess the relationship between sensitivity and specificity (area under the ROC curve). The influence of intra-canal material and software used was verified by an analysis of variance model (ANOVA) and pairwise comparisons performed using Tukey test, considering a significance level of 5%. Overall, there was not a statistically significant difference between softwares. Thus, the efficiency of the software was similar among them when the same condition (type of material present inside the canal) was shown. However, there was a statistically significant difference between the materials, considering accuracy, sensitivity and area under the ROC curve. Compared with UR and GP groups, the accuracy of diagnosis was significantly lower in the Post group when any software was used (p <0.05). In conclusion, the diagnosis of root fracture does not depend on the software, which means that the professional should choose the one of his preference. However attention should be drawn to the fact that, regardless of the software used, the presence of metallic post decreases the chance of a correct diagnosis / Doutorado / Radiologia Odontologica / Doutor em Radiologia Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/288977
Date22 August 2018
CreatorsMelo, Saulo Leonardo Sousa, 1982-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Haiter Neto, Francisco, 1964-, Correa, Márcio, Santos, Christiano de Oliveira, Santos, Rívea Inês Ferreira, Martins, Luís Roberto Marcondes
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Radiologia Odontológica
Source SetsIBICT Brazilian ETDs
LanguageMultilíngua
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format66 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0021 seconds