Made available in DSpace on 2014-06-11T19:26:10Z (GMT). No. of bitstreams: 0
Previous issue date: 2009-10-02Bitstream added on 2014-06-13T20:33:56Z : No. of bitstreams: 1
bortolin_jrm_me_rcla.pdf: 3726642 bytes, checksum: a4355e8e190b22200038d53f9e35e03e (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Este trabalho contempla um monitoramento temporal da pluma de contaminação do aterro controlado de Rio Claro (SP), por meio do Método da Eletrorresistividade, comparando-se resultados de Imageamentos Elétricos, com arranjo Dipolo-Dipolo, executados nos anos de 1999 e 2008. A base desse método reside em que diferentes materiais, geológicos ou não, apresentam diferentes valores de resistividade elétrica, sendo essa um parâmetro intrínseco dos materiais, o qual se relaciona à dificuldade encontrada por uma corrente elétrica para se propagar em um meio. O chorume gerado em aterros acaba por diminuir a resistividade elétrica do meio natural circunvizinho, caracterizando a contaminação. Assim, zonas de baixa resistividade, com valores menores ou iguais a 50Ω.m, foram associadas à contaminação por chorume. A interpretação conjunta das seções de resistividade aparente permitiu identificar alterações das dimensões da pluma de contaminação no decorrer dos anos. Regida pelos fluxos principal e secundário, a pluma de contaminação avançou em direção aos limites oeste e sul do aterro. Complementarmente, Sondagens Elétricas Verticais permitiram verificar a profundidade do nível freático e o sentido do fluxo d’água, além da caracterização geoelétrica das litofácies sobre as quais está assentado o aterro: sedimentos predominantemente arenosos da Formação Rio Claro e sedimentos predominantemente siltosos da Formação Corumbataí. / This work describes a temporal monitoring of the contamination plume from the controlled landfill of Rio Claro (SP), through the resistivity method, comparing the Electroresistivity Profiling’s results, with Dipole-Dipole array, carried out in 1999 and 2008. The basis of this method lies in that different materials, geological or not, have different values of resistivity, and this is an intrinsic material parameter, which relates to the difficulty experienced by an electric current to propagate in a body. The leachates produced on the landfill diminish the electrical resistivity of the natural ambient, characterizing the contamination. Thus, zones of low resistivity, with values smaller or same a 50ohm.m, had been associates to the contamination for landfill wastewater. The joint interpretation of the sections of apparent resistivity allowed to identify alterations of the dimensions of the contamination plume in elapsing of the years. Governed by the main and secondary flows, the contamination plume advanced in direction to the limits west and soul of controlled landfill. Complementarily, Vertical Electrical Soundings had allowed to verify the depth and the direction of the underground water flow, and to characterize geo-electrically the lithology on which is seated the controlled landfill: sediments predominantly sandy of the Rio Claro Formation and sediments predominantly silty of the Corumbataí Formation.
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/92750 |
Date | 02 October 2009 |
Creators | Bortolin, José Ricardo Melges [UNESP] |
Contributors | Universidade Estadual Paulista (UNESP), Malagutti, Walter [UNESP] |
Publisher | Universidade Estadual Paulista (UNESP) |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | English |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | 134 f. : il., tabs. + 1 CD-ROM |
Source | Aleph, reponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP |
Rights | info:eu-repo/semantics/openAccess |
Relation | -1, -1 |
Page generated in 0.0029 seconds