Return to search

Compressão de sinais de eletromiografia explorando correlação bidimensional

Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2008. / Submitted by Tania Milca Carvalho Malheiros (tania@bce.unb.br) on 2009-07-30T13:01:18Z
No. of bitstreams: 1
Dissert_MarcusViniciusChaffimCosta.pdf: 1895813 bytes, checksum: 2786747a5eca0d0550a1abe8eaa000d9 (MD5) / Rejected by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br), reason: on 2009-07-31T12:23:53Z (GMT) / Submitted by Tania Milca Carvalho Malheiros (tania@bce.unb.br) on 2009-07-31T12:36:31Z
No. of bitstreams: 1
Dissert_MarcusViniciusChaffimCosta.pdf: 1895813 bytes, checksum: 2786747a5eca0d0550a1abe8eaa000d9 (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2009-07-31T14:19:26Z (GMT) No. of bitstreams: 1
Dissert_MarcusViniciusChaffimCosta.pdf: 1895813 bytes, checksum: 2786747a5eca0d0550a1abe8eaa000d9 (MD5) / Made available in DSpace on 2009-07-31T14:19:26Z (GMT). No. of bitstreams: 1
Dissert_MarcusViniciusChaffimCosta.pdf: 1895813 bytes, checksum: 2786747a5eca0d0550a1abe8eaa000d9 (MD5)
Previous issue date: 2008-03-07 / Nesta pesquisa é apresentada uma análise da correlação bidimensional de sinais
eletromiográficos de superfície obtidos a partir de esforços isométricos e isotônicos. Para tanto, cada sinal foi segmentado em janelas contíguas e estas então concatenadas a fim de produzir uma matriz bidimensional. O tamanho dessas janelas foi variado para que se pudesse avaliar a sua influência no cálculo do coeficiente de correlação entre um sub-bloco contendo a maior parte do sinal, deslocado ao longo das amostras e ao longo das janelas, e a própria matriz bidimensional. Observada uma correlação bidimensional nas matrizes
assim construídas, foi implementado um algoritmo de compressão de sinais de
eletromiografia de superfície baseado em um método bastante eficiente para compressão de sinais bidimensionais, o JPEG2000. Apesar do JPEG2000 ser desenvolvido para comprimir imagens, observou-se que também pode ser usado para comprimir sinais eletromiográficos, tanto de contrações isométricas quanto de contrações isotônicas. Para sinais de eletromiografia de superfície obtidos durante contrações isométricas, o algoritmo proposto conseguiu fatores de compressão que vão de 75 a 90%, com uma raiz da diferença média percentual média na faixa de 3,75% to 13,7%. Para sinais de eletromiografia de superfície adquiridos de contrações isotônicas, o algoritmo produziu fatores de compressão de 75 a 90% com uma raiz da diferença média percentual média entre 3,4 e 7%. Os resultados da compressão usando JPEG2000 foram comparados com outros algoritmos baseados em transformada de wavelets. Este trabalho mostrou que a
compressão pelo método proposto apresenta resultado compatível com os algoritmos apresentados na literatura, e, no caso de sinais isotônicos, para fatores de compressão acima de 80%, o seu resultado foi superior àqueles com os quais foi comparado.
________________________________________________________________________________________ ABSTRACT / In this research we present the analysis of two-dimensional correlation of surface
electromyographic signals obtained from isometric and isotonic efforts. Thus, we splited each signal in contiguous windows and organize them to produce a two-dimensional matrix. The size of these windows was varied so that it could assess its influence in the calculation of the coefficient of correlation between a sub-block, moved along the samples and along the windows, containing most of the signal, and the image itself. Shown a correlation in these two-dimensional matrices well built, has been implemented na algorithm for compression of electromyographic signals based on a method that is very effective for the compression of still images, the JPEG2000 algorithm. Although the JPEG2000 codec is designed to compress images, was illustrated that it can also be used to compress surface electromyographic signals for both isotonic and isometric contractions. For surface electromyographic signals acquired during isometric contractions, the proposed
algorithm provided compression factors ranging from 75 to 90%, with an average
percentage root mean difference ranging from 3,75% to 13,7%. For the isotonic surface electromyographic signals, the algorithm provided compression factors ranging from 75 to 90%, with an average percentage root mean difference ranging from 3,4% to 7%. The compression results using the JPEG2000 algorithm were compared to other algorithms based on the wavelet transform. This work has shown that the compression method proposed presents results compatible with the algorithms in the literature, and in the case of isotonic signals, for compression factors above 80%, the result was better than those compared with.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unb.br:10482/1550
Date07 March 2008
CreatorsCosta, Marcus Vinícius Chaffim
ContributorsNascimento, Francisco Assis de Oliveira
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UnB, instname:Universidade de Brasília, instacron:UNB
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0028 seconds