Return to search

Implementing Usability Engineering into Development of an Innovative Antibiotic Susceptibility Testing Device

During the last decades, newly developed medical devices often came along with unappropriate designs, increasing the likelihood of misuse through the operator. Part of the root cause was that no sufficient measures were applied to assimilate user needs. Consequently, usability engineering approaches are now stronger emphasized to ensure that new devices are not only safe to use but are also designed for users’ needs. Besides, testing processes in clinical microbiology laboratories are currently reshaped due to new generations of rapid testing methods. Hence, it is particularly important to apply usability engineering frameworks during the development phase to make sure devices address users’ needs and also fit into the new work- and communication flows. Based on that, this research project applies a usability engineering approach to the design process of a new rapid antibiotic susceptibility testing system of Astrego Diagnostic AB that is supposed to be used in clinical microbiology laboratories in the near future. The research questions focus on how this device can be designed to enable integration into clinical laboratories. -       How can a rapid AST testing system be integrated into the workflow of clinical microbiology laboratories? -       What are the remaining uncertainties for integrating a rapid AST system into the workflow of a clinical microbiology laboratory on the example of Astrego’s AST system? Several methods were used to address these questions, which include literature research, a competitive audit, subject matter interviews and semi-structured interviews, and observations of targeted users. The findings show that a rapid antibiotic susceptibility testing system may be used in several different ways, which also impacts its design. Process-wise, it could be used after Gram staining and bacterial identification has been conducted and, more realistically, simultaneously bacterial identification to pave the way for additional time savings further. However, uncertainties remain regarding the design of the new testing system. Depending on the number of devices that targeted laboratories need to implement to accommodate their testing volume, it makes sense to design a built-in user interface or an external one that can be accessed through a tablet or desktop. Thus, it is uncertain to what extent manual input of bacteria ID is relevant as the dRAST system fully enables manual input of Gram type and bacteria IDs while it might also be possible to avoid manual interaction by receiving this information through software interfaces.

Identiferoai:union.ndltd.org:UPSALLA1/oai:DiVA.org:uu-396589
Date January 2019
CreatorsScheuring, Toni
PublisherUppsala universitet, Industriell teknik
Source SetsDiVA Archive at Upsalla University
LanguageEnglish
Detected LanguageEnglish
TypeStudent thesis, info:eu-repo/semantics/bachelorThesis, text
Formatapplication/pdf
Rightsinfo:eu-repo/semantics/openAccess
RelationTVE-MILI ; 19038

Page generated in 0.0019 seconds