Return to search

Bioatividade de vidros contendo nióbio : estudo experimental in vivo / Bioactivity of glasses composed by niobium : an experimental in vivo study

Orientador: José Angelo Camilli / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Biologia / Made available in DSpace on 2018-08-25T16:59:30Z (GMT). No. of bitstreams: 1
Souza_LucasPereiraLopesde_M.pdf: 1756933 bytes, checksum: 1c3778ee02f4dd8104d6a216a95db04b (MD5)
Previous issue date: 2014 / Resumo: Alguns estudos mostram que a introdução do óxido de nióbio (Nb2O5) na composição do Bioglass® poderia ser uma solução para melhorar sua resistência mecânica, mantendo sua biocompatibilidade e bioatividade, porém, apesar da melhora na resistência mecânica causada pela adição deste óxido ser bem documentada na literatura, suas propriedades bioativas ainda são pouco conhecidas. Neste contexto, o objetivo do presente estudo foi avaliar experimentalmente as propriedades bioativas do óxido de nióbio em ratos albinos (Rattus norvegius) da linhagem Wistar. Para isso, bastões vítreos compostos por diferentes concentrações do Nb2O5 foram implantados na tíbia de ratos. Além disso, cada vidro teste, na forma de pó, foi implantado no músculo de ratos para análise de suas propriedades pró-angiogênicas, usando o Bioglass 45S5 (Bioglass®) como controle. As eutanásias foram realizadas 14 e 28 dias pós-cirurgias. Lâminas histológicas de cortes transversais das tíbias foram coradas a H&E para mensuração da área de osso subperiostal existente na cortical adjacente ao implante e a quantidade de osso esponjoso formado ao redor do bastão vítreo nos grupos de 14 dias, bem como da espessura da lâmina óssea formada ao redor do bastão nos grupos de 28 dias. Foi ainda realizada marcação imuno-histoquímica e a razão entre a área total do implante em mm2 e o número total de vasos sanguíneos contados manualmente num aumento de 400x para verificação a capacidade do material de estimular a angiogênese. A avaliação histológica revelou a ausência total de inflamação tanto após 14 quanto após 28 dias de implante. Os resultados das comparações entre as áreas de osso subperiostal dos grupos após 14 e 28 dias (feitas através de um teste ANOVA com post hoc tukey) e da quantidade de osso esponjoso formado ao redor do implante nos grupos 14 dias (feitas através do teste Kruskal-Wallis com Mann-Whitney como post hoc) mostraram que o BGPN1.3 apresentou maior capacidade de induzir a formação óssea do que o grupo controle, já com relação ao número de vasos sanguíneos e espessura da lâmina óssea formada ao redor do implante todos os grupos apresentaram resultado semelhantes. Assim, se concluiu que o BGPN1.3 trata-se de um material inovador por ser biocompatível, apresentar propriedade osteoindutiva superior e capacidade pró-angiogênica semelhante ao Bioglass® / Abstract: Some studies show that the introduction of niobium oxide (Nb2O5) into Bioglass® composition could be a solution to improve its mechanical strength while maintaining its biocompatibility and bioactivity, but in spite of improvement in resistance caused by addition of the oxide is well documented in the literature, their bioactive properties are still poorly known. In this context, the aim of this study was to experimentally evaluate the bioactive properties of niobium oxide in albino rats (Rattus norvegius). For this, glassy rods composed of different concentrations of Nb2O5 were implanted in the rats¿ tibia. In addition, each test glass in powder form was implanted into the muscle of mouse for analysis of their pro-angiogenic properties using 45S5 Bioglass (Bioglass®) as control. Euthanasia were performed 14 and 28 days post-surgery. Histological slides of cross sections of tibiae were H & E stained for measuring the area of existing subperiosteal bone in adjacent to the implant and the amount of cancellous bone formed around the vitreous rod after 14 days pos-surgery as well as the thickness of the formed bone sheet around the rod in groups of 28 days. It was also performed immunohistochemical staining to calculate the ratio between the total area in mm2 of the implant and the total number of blood vessels, counted manually using a magnification of 400x, to check the capacity of the material to stimulate angiogenesis. Histological evaluation revealed the complete absence of inflammation after both 14 and after 28 days of implantation. The results of the comparisons between the areas of subperiosteal bone of groups after 14 and 28 days (made by an ANOVA with Tukey post hoc test) and the amount of cancellous bone formation around the implant in the groups 14 days (done by Kruskal -Wallis with Mann-Whitney post hoc) revealed that BGPN1.3 showed greater ability to induce bone formation than the control group, when compared the number of blood vessels and thickness of the blade bone formed around the implant all groups showed similar results. Thus, we concluded that BGPN1.3 is an innovative material to be biocompatible and display better osteoinductive property than Bioglass® showing similar pro-angiogenic capacity / Mestrado / Anatomia / Mestre em Biologia Celular e Estrutural

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/317638
Date25 August 2018
CreatorsSouza, Lucas Pereira Lopes de, 1989-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Camilli, Jose Angelo, 1963-, Araújo, Rodrigo Cappato de, Soares, Evelise Aline
Publisher[s.n.], Universidade Estadual de Campinas. Instituto de Biologia, Programa de Pós-Graduação em Biologia Celular e Estrutural
Source SetsIBICT Brazilian ETDs
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format48 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess