Return to search

Dynamic soil-structure interaction of reinforced concrete buried structures under the effect of dynamic loads using soil reinforcement new technologies. Soil-structure interaction of buried rigid and flexible pipes under geogrid-reinforced soil subjected to cyclic loads

Recent developments in constructions have heightened the need for protecting existing buried infrastructure. New roads and buildings may be constructed over already existing buried infrastructures e.g. buried utility pipes, leading to excessive loads threatening their stability and longevity. Additionally applied loads over water mains led to catastrophic damage, which result in severe damage to the infrastructure surrounding these mains. Therefore, providing protection to these existing buried infrastructure against increased loads due to new constructions is important and necessary.
In this research, a solution was proposed and assessed, where the protection concept would be achieved through the inclusion process of geogrid-reinforcing layers in the soil cover above the buried infrastructure. The controlling parameters for the inclusion of geogrid-reinforcing layers was assessed experimentally and numerically. Twenty-three laboratory tests were conducted on buried flexible and rigid pipes under unreinforced and geogrid-reinforced sand beds. All the investigated systems were subjected to incrementally increasing cyclic loading, where the contribution of varying the burial depth of the pipe and the number of the geogrid-reinforcing layers on the overall behaviour of the systems was investigated. To further investigate the contribution of the controlling parameters in the pipe-soil systems performance, thirty-five numerical models were performed using Abaqus software. The contribution of increasing the amplitude of the applied cyclic loading, the number of the geogrid-reinforcing layers, the burial depth of the pipe and the unit-weight of the backfill soil was investigated numerically.

The inclusion of the geogrid-reinforcing layers in the investigated pipe-soil systems had a significant influence on decreasing the transferred pressure to the crown of the pipe, generated strains along its crown, invert and spring-line, and its deformation, where reinforcing-layers sustained tensile strains. Concerning rigid pipes, the inclusion of the reinforcing-layers controlled the rebound that occurred in their invert deformation. With respect to the numerical investigation, increasing the number of the reinforcing-layers, the burial depth of the pipe and the unit-weight of the backfill soil had positive effect in decreasing the generated deformations, stresses and strains in the system, until reaching an optimum value for each parameter. Increasing the amplitude of the applied loading profile resulted in remarkable increase in the deformations, stresses and strains generated in the system. Moreover, the location of the maximum tensile strain generated in the soil was varied, as well as the reinforcing-layer, which suffered the maximum tensile strain. / Government of Egypt

Identiferoai:union.ndltd.org:BRADFORD/oai:bradscholars.brad.ac.uk:10454/18312
Date January 2019
CreatorsElshesheny, Ahmed
ContributorsMohamed, Mostafa H.A., Sheehan, Therese
PublisherUniversity of Bradford, Faculty of Engineering and Informatics University of Bradford
Source SetsBradford Scholars
LanguageEnglish
Detected LanguageEnglish
TypeThesis, doctoral, PhD
Rights<a rel="license" href="http://creativecommons.org/licenses/by-nc-nd/3.0/"><img alt="Creative Commons License" style="border-width:0" src="http://i.creativecommons.org/l/by-nc-nd/3.0/88x31.png" /></a><br />The University of Bradford theses are licenced under a <a rel="license" href="http://creativecommons.org/licenses/by-nc-nd/3.0/">Creative Commons Licence</a>.

Page generated in 0.0026 seconds