Study on Electric-Arc Characteristics and Formation Mechanism of Erosion for DC Silver Contacts in Inert Gas.

Abstract
In this study, a static electric contact tester with a vacuum system and gas supply system is used to investigate the effects of experimental parameters, such as inert gas kind, supply voltage, and the gap between the contacts, on the electric-arc characteristics and the erosion type for the electric contacts of silver. The experimental results show that chargeable threshold voltage in helium is higher than that in argon or air. In addition, the erosion surface of anode is observed, and the erosion area and volume are calculated and analyzed. Results show that the erosion area and volume in helium are smaller than that in argon or air. According to the observation of SEM photomicrographs, metal sputtering of the erosion hole in helium is smaller than that in argon or air. It is expected to provide the domestic electrical contact manufacturer in improving the research and development technique of the electrical contacts, and the design reference related to ultra-precision machining using a clean room.