In this study, a tension leg platform (TLP) incorporated with the TLCD (Tuned liquid column damper) is tested experimentally. The advantages of TLP with TLCD devices are as follows¡G1.When the TLCD devices use on the TLP, the columns under the platform could provide the buoyant force. 2. When the TLCD devices are injected into water, the vibration of the platform could be mitigated by the water sloshing power. 3. It can change the natural frequency within limits by changing the liquid length.
In this thesis, a scaled-down model is tested in the laboratory to verify the analytical results. When the experiment tested, the total mass of the system should be the same no matter if the TLCD devices are applied or not. We used the accelerometers to obtained the acceleration of the platform including the surge, heave and pitch motions. The tendon force is obtained by the strain gage.
Can be found from the experiment course, after the structure adds the TLCD devices, the responses of three motion can be effective reduced. So what reducing shaking to disappear and can be designed and discussed best by this text under various kinds of situations of finding out.
Identifer | oai:union.ndltd.org:NSYSU/oai:NSYSU:etd-0907104-130355 |
Date | 07 September 2004 |
Creators | Chen, Tai-ming |
Contributors | H-h Lee, Fau-fang Lee, Yang-yih Chen |
Publisher | NSYSU |
Source Sets | NSYSU Electronic Thesis and Dissertation Archive |
Language | Cholon |
Detected Language | English |
Type | text |
Format | application/pdf |
Source | http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0907104-130355 |
Rights | unrestricted, Copyright information available at source archive |
Page generated in 0.0021 seconds