Return to search

Punção em lajes lisas com pilar de borda protendidas com cordoalhas não aderentes

Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2008. / Submitted by Jaqueline Ferreira de Souza (jaquefs.braz@gmail.com) on 2009-09-23T20:19:57Z
No. of bitstreams: 1
2008_MarcosHonoratoOliveira.pdf: 4642102 bytes, checksum: a12b2d8203feedcdc8b7c4fbf80c530e (MD5) / Approved for entry into archive by Gomes Neide(nagomes2005@gmail.com) on 2010-07-05T20:47:40Z (GMT) No. of bitstreams: 1
2008_MarcosHonoratoOliveira.pdf: 4642102 bytes, checksum: a12b2d8203feedcdc8b7c4fbf80c530e (MD5) / Made available in DSpace on 2010-07-05T20:47:40Z (GMT). No. of bitstreams: 1
2008_MarcosHonoratoOliveira.pdf: 4642102 bytes, checksum: a12b2d8203feedcdc8b7c4fbf80c530e (MD5)
Previous issue date: 2008-08 / Serão apresentados neste trabalho resultados experimentais dos ensaios de oito modelos
locais de ligação laje/pilar de borda. Este trabalho faz parte da primeira série de ensaios da
tese de doutorado de Helder Pontes Gomes na Universidade de Brasília, no ano de 2008.
Buscou-se por meio desses ensaios avaliar a influência da relação do momento fletor
dividido pela força cortante (M/V), da relação c/d, da presença de overhang em alguns dos
modelos e do nível de protensão na resistência à punção para o cálculo da ligação laje/pilar
de borda de lajes protendidas. Foram realizadas também comparações entre os resultados
experimentais e as previsões analíticas estabelecidas pela NBR 6118:2003 e por algumas
normas internacionais de referência, como o ACI 318M-02 e o EUROCODE 2:2001, para
então verificar se as formulações preconizadas pelas normas acima são convenientes.
Algumas das análises realizadas indicaram que o acréscimo de tensão nos cabos está
diretamente associado ao tipo de carregamento aplicado. As deformações sofridas pelo
concreto tiveram influência da disposição dos cabos de protensão. A presença de overhang
aumenta a rigidez da ligação, influencia no padrão de fissuração e na forma do cone de
ruptura.
As comparações com as normas mostraram que a NBR 6118:2003 (média: 3,11 e desvio
padrão: 0,38) apresentou um menor desempenho em relação a todas as outras normas
avaliadas. O ACI 318M-02 (média: 2,56 e desvio padrão: 0,26), embora menos que a NBR
6118:2003, também se apresentou bastante conservador por ter em sua formulação
limitações para resistência característica do concreto e eficácia da protensão em pilares de
borda com distância à borda inferior a 4.d. Sem a consideração das restrições para
resistência característica e eficácia da protensão em pilares de borda, foi analisado assim
chamado ACI* 318M-02, que apresentou os melhores resultados para todos os modelos
ensaiados com média igual a 1,29 e desvio padrão igual a 0,14. Como esse não se trata de
norma em vigor o melhor desempenho para as normas foi do EUROCODE 2:2001, com
média igual a 1,84 e desvio padrão igual a 0,24. Todas as normas analisadas mostraram-se
não estarem ajustadas para relação c/d maior que 2,0 e para a contribuição do overhang na carga de ruptura. __________________________________________________________________________________ ABSTRACT / Were presented in this work results and analysis of eight local models of slabs-edge
columns connections with post tensioned unbounded tendons tested in University of
Brasilia. Those tests are simultaneously part of the first series of experimental tests for the
doctorate thesis of Helder Pontes Gomes.
The intent of this work was evaluate the influence of the bending moment/shear force
(M/V), c/d relation, the level of post tension and the presence of overhang in some of
specimens in the pushing shear resistance of post tensioned flat slab-edge columns
connections. Were made comparisons of those results with analytical predictions
established by NBR 6118:2003 and some others relevant international codes, being them:
ACI 318M-02 and EUROCODE 2:2001, and made considerations about the efficiency of
the formulations of each of them.
The analysis of the tension of the tendons shows that increase of the tensions during the
test is directly related with the applied load. The deformation of the inferior surface of the
concrete around the connection was influenced by the arrangement of the tendons and by
the presence of the overhang. The presence of the overhang enhances the connection
rigidity and influence the standard of cracking and the shape of the truncated cone of
failure.
The carried out analysis of the codes showed that the NBR 6118:2003 (average: 3,11 and
standard deviation: 0,38) as the more conservative code among those studied. The ACI
318M-02 code (average: 2,56 and standard deviation: 0,26), although less than the NBR
6118:2003, was fairly conservative because of the restrictions to concrete strength and
effectiveness of the post tension in slab-edge columns connections. Without these
restrictions, the called ACI* 318M-02 become the code with better performance for all
specimens, with 1,29 of average and 0,14 of standard deviation. But as this code is not
available, the code that had better performance for connections tested was EUROCODE
2:2001, with 1,84 of average and 0,24 of standard deviation. All codes analyzed showed
not be adjusted to range of c/d larger than 2,0 and to the contribution of the overhang in the
evaluation of the failure load.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unb.br:10482/5189
Date08 1900
CreatorsOliveira, Marcos Honorato de
ContributorsMelo, Guilherme Sales Soares de Azevedo
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UnB, instname:Universidade de Brasília, instacron:UNB
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0026 seconds