Lead-acid batteries are the oldest and most common type of secondary cells. Their biggest use is as a power source for a car starter. Bipolar lead-acid batteries could also be used for new applications such as power sources for hybrid electrical vehicles (HEV) for their high power. But there are still many technical problems limiting its use in these applications, which have to be overcome. This could cover parasite reactions as is gas creation, heat removal from the battery and another big problem is substrate corrosion. This diploma thesis concerns the actual state of bipolar lead batteries in the world with detail orientation to substrate corrosion. This thesis describes the conductometric method of lotion conductivity measurement and its modification for measurement of lead grid conductivity. From that we can find out, that when material loses more conductivity, the greater the corrosion. This thesis describes needed preparative experiments for assurance, that the conductometric method can be used for corrosion speed measurement and there are other experiments testing different lead alloys for corrosion speed.